3d mri gel dosimetry based on image intensity (a new approach)
نویسندگان
چکیده
background: since 1984 mri gel dosimetry has been introduced as a potential technique for 3d dosimetry. most of the studies have measured r1 (1/t1) or r2 (1/t2) properties of the gel depending on the gel type. we have studied image intensity change in the fricke gel by different mri protocols. materials and methods: gel dosimeters contain 0.4 mm ferrous sulphate, 1 mm nacl, 50 mm h2so4 and 1% by weight agarose in distilled water. prepared gels were poured in plastic tube phantom and irradiated to a beam of co-60 gamma rays. imaging was performed by a 0.5t mri system in the head coil with se and gre techniques. results: our results showed that linear response exists between the variations of image intensity with absorbed dose (1-15 gy). optimal imaging parameters should be defined locally according to the type of mri scanner and exact composition of the gel. gradient echo (gre) imaging technique also have been studied in comparison with classic spin echo (se) imaging technique which will be discussed in detail. conclusions: linearity of absorbed dose with intensity exists up to 15 gy and can be used for mri gel dosimetry. reduction of imaging time is achievable in image intensity technique so that it’s possible to image the gel in less than 20 minutes, which is critical to over-come the adverse ion-diffusion properties of the fricke gel. iran . j. radiat. res., 2003 1(1): 45 - 50.
منابع مشابه
3D MRI gel dosimetry based on image intensity (A new approach)
Background: Since 1984 MRI gel dosimetry has been introduced as a potential technique for 3D dosimetry. Most of the studies have measured R1 (1/T1) or R2 (1/T2) properties of the gel depending on the gel type. We have studied image intensity change in the Fricke gel by different MRI protocols. Materials and Methods: Gel Dosimeters contain 0.4 mM ferrous sulphate, 1 mM NaCl, 50 mM H2SO4 and 1% b...
متن کاملA new approach to contrast enhancement in MAGICA gel dosimeter image with MRI technique
parameters that have to be measured in gel dosimetry. However, the resolution in gel is strongly dependant on gel composition. Selection of optimum method in dose response readout and proper values of parameters can result in noise reduction as well as improvement of contrast, and spatial resolution considerably. Materials and Methods: MAGICA polymer gel dosimeters were manufactured and irradia...
متن کاملUncertainty Analysis in MRI-based Polymer Gel Dosimetry
Background: Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin I...
متن کاملa new approach to contrast enhancement in magica gel dosimeter image with mri technique
parameters that have to be measured in gel dosimetry. however, the resolution in gel is strongly dependant on gel composition. selection of optimum method in dose response readout and proper values of parameters can result in noise reduction as well as improvement of contrast, and spatial resolution considerably. materials and methods: magica polymer gel dosimeters were manufactured and irradia...
متن کاملUncertainty in 3D gel dosimetry
Three-dimensional (3D) gel dosimetry has a unique role to play in safeguarding conformal radiotherapy treatments as the technique can cover the full treatment chain and provides the radiation oncologist with the integrated dose distribution in 3D. It can also be applied to benchmark new treatment strategies such as image guided and tracking radiotherapy techniques. A major obstacle that has hin...
متن کاملUncertainty Analysis in MRI-based Polymer Gel Dosimetry
BACKGROUND Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin In...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of radiation researchجلد ۱، شماره ۱، صفحات ۴۵-۵۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023