1h qnmr approach for estimation of a toxic compound n,n-dimethylamine in metformin hydrochloride: an equivalent efficient method over reversed phase derivatization hplc method
نویسندگان
چکیده
a rapid, specific and accurate proton quantitative nuclear magnetic resonance spectroscopic (1h qnmr) and also a reversed phase derivatization hplc method have been developed to quantify a toxic, uv-visible inactive and non-volatile impurity n,n-dimethylamine hydrochloride (dma∙hcl) in metformin hydrochloride (mf∙hcl), an active pharmaceutical ingradient. the method is based on proton quantitative nmr spectroscopy (1h qnmr) using glycine as internal standard and deuterium oxide (d2o) as diluent. both the methods have been validated as per the parameters of ich guidelines and are found to be comparable.the advantages of the proposed 1h qnmr method are that no certified reference standard of dma∙hcl is required for quantification, the method is specific, non-destructive and can be applied for quantification of dma∙hcl in process, quality control for the manufacturing of metformin hydrochloride as well as commercial dosage form products.
منابع مشابه
A Novel RP-HPLC Method for Simultaneous Estimation of Metformin Hydrochloride & Glimepiride in Tablet Dosage Form
A new simple, fast accurate and reproducible reverse phase high performance liquid chromatographic method has been developed and validated for simultaneous estimation of Metformin Hydrochloride and Glimepiride from tablet dosage form. The method was developed using Waters HPLC system on C18 column (Spherisorb ODS 2: 250mm x 4.6 μm) using a mixture of 25mM Phosphoric Acid pH 3.0 (with KOH) and A...
متن کاملDevelopment and Validation of Reversed Phase Hplc Method for Estimation of Ceftriaxone in Pharmaceutical Dosage Form
Ceftriaxone sodium (Figure 1) is chemically (6R,7R)-7[[(2Z)-(2-amino-4thiazolyl)(methoxyimino)acetyl]amino]-8-oxo-3[[(1,2,5,6-tetrahydro-2-methyl-5,6-ioxo-1,2,4-triazin3-yl)thio]-methyl]-5-thia-1-azabicyclo[4.2.0]oct-2-ene2-carboxylic acid 1 . Ceftriaxone is a third generation, semisynthetic cephalosporin antibiotic. Cephalosporins are derivatives of 7aminocephalosporic acid and are closely rel...
متن کاملDevelopment and validation of reversed-phase HPLC gradient method for the estimation of efavirenz in plasma
Efavirenz is an anti-viral agent of non-nucleoside reverse transcriptase inhibitor category used as a part of highly active retroviral therapy for the treatment of infections of human immune deficiency virus type-1. A simple, sensitive and rapid reversed-phase high performance liquid chromatographic gradient method was developed and validated for the determination of efavirenz in plasma. The me...
متن کاملreversed phase high performance liquid chromatographic method for simultaneous estimation of eperisone hydrochloride and paracetamol in tablet dosage form
eperisone hydrochloride is a skeletal muscle relaxant and paracetamol is cyclooxygenase inhibitor. these drugs in combination are used as antispasmodics. a simple, specific, precise and accurate method was developed, namely reverse phase high performance liquid chromatography for simultaneous estimation of eperisone hydrochloride and paracetamol in tablet dosage form. in rp-hplc method separati...
متن کاملDevelopment and validation of a reversed-phase HPLC method for analysis of tetrahydrozoline hydrochloride in eye drop formulations
A simple, precise, accurate, and stability-indicating method is developed and validated for analysis of tetrahydrozoline hydrochloride in eye drop formulations. Separation was achieved on a reversed-phase C8 column (125 mm×4.6 mm i.d., 5 μm) using a mobile phase consisting of acetonitrile/phosphate buffer of pH 3.0 (20:80, v/v) at a flow rate of 1.0 mL/min and UV detection at 240 nm. This metho...
متن کاملDevelopment And Validation Of A Hplc Method For The Determination Of Metformin Hydrochloride, Gliclazide And Piogliglitazone Hydrochloride In Multicomponent Formulation
A simple, rapid, and precise reversed-phase high-performance liquid chromatographic method for simultaneous analysis of metformin hydrochloride, gliclazide, and pioglitazone hydrochloride in a tablet dosage form has been developed and validated. Chromatography was performed on a 25 cm × 4.6 mm i.d., 5-μm particle, C18 column with 85:15 (v/v) methanol: 20 mM potassium dihydrogen phosphate buffer...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of analytical chemistryناشر: payame noor university, iran
ISSN 2383-2207
دوره 2
شماره 2 2015
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023