staff and patient absorbed doses due to diagnostic nuclear medicine procedures

نویسندگان

f. tabeie

i. neshandar asli

s.m. aghamiri

k. arbabi

چکیده

background: annual patient effective dose equivalent can be considered as a quantitative physical parameter describing the activities performed in each nuclear medicine department. annual staff dose equivalent could be also considered as a parameter describing the amount of radiation risk for performing the activities. we calculated the staff to patient dose equivalent ratio to be used as a physical parameter for quantification of alara law in nuclear medicine departments. materials and methods: as a part of nationwide study, this paper reports the staff and patient absorbed dose equivalents from diagnostic nuclear medicine examinations performed in four nuclear medicine departments during 1999-2002. the type and frequency of examinations in each department were determined directly from hospital medical reports. staff absorbed dose equivalents were calculated from regular personal dosimeter reports. results: the total number of examinations increased by 16.7% during these years. annual patient collective dose equivalent ( ede ) increased about 13.0% and the mean effective dose equivalent per exam was 3.61±0.07 msv. annual total staff absorbed dose equivalent (total of 24 radiation workers) in four departments increased from 40.45 msv to 47.81 msv during four years that indicates an increase of about 20.6%. the average of annual ratios of staff to patient effective dose equivalents in four departments were 1.83×10-3, 1.04×10-3, 3.28×10-3 and 3.24×10-3, respectively, within a range of 0.9×10-3 – 4.17×10-3 . the mean value of ratios in four years was about 2.24×10-3 ± 1.09×10-3 that indicates the staff dose of about two 1000th of patient dose. conclusion: the mean value of ratios in four years was about 1.89×10-3 ± 0.95×10-3 indicating the staff dose of about one 1000th of the patient dose. the staff to patient absorbed dose equivalent ratio could be used as a quantitative parameter for describing alara law in radiation protection and risk-benefit assessments. iran . j. radiat. res., 2004 2 (2): 63-68

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Staff and patient absorbed doses due to diagnostic nuclear medicine procedures

Background: Annual patient effective dose equivalent can be considered as a quantitative physical parameter describing the activities performed in each nuclear medicine department. Annual staff dose equivalent could be also considered as a parameter describing the amount of radiation risk for performing the activities. We calculated the staff to patient dose equivalent ratio to be used as a phy...

متن کامل

Finger doses for staff handling radiopharmaceuticals in nuclear medicine.

UNLABELLED Radiation doses to the fingers of occupational workers handling 99mTc-labeled compounds and 131I for diagnostic and therapeutic procedures in nuclear medicine were measured by thermoluminescence dosimetry. METHODS The doses were measured at the base of the ring finger and the index finger of both hands in 2 groups of workers. Group 1 (7 workers) handled 99mTc-labeled radiopharmaceu...

متن کامل

Patient exposure to ionising radiation due to nuclear medicine cardiac procedures.

Nuclear cardiology procedures are among the most extensively performed radionuclide studies. Procedures for the assessment of myocardial perfusion, contractile function and metabolism have gained a prominent position in clinical practice. Health risk to patients from radiopharmaceuticals results only from exposure to ionizing radiation. Nuclear medicine diagnostic procedures,including the cardi...

متن کامل

Effective doses in radiology and diagnostic nuclear medicine: a catalog.

Medical uses of radiation have grown very rapidly over the past decade, and, as of 2007, medical uses represent the largest source of exposure to the U.S. population. Most physicians have difficulty assessing the magnitude of exposure or potential risk. Effective dose provides an approximate indicator of potential detriment from ionizing radiation and should be used as one parameter in evaluati...

متن کامل

Patient exposures and consequent risks from nuclear medicine procedures.

PATIENT EXPOSURES AND CONSEQUENT RISKS FROM NUCLEAR MEDICINE PROCEDURES

متن کامل

Absorbed radiation doses to staff after implementation of a radiopharmacy clean room.

UNLABELLED In response to U.S. Pharmacopeia general chapter <797> standards, a clean room was constructed for our in-house radiopharmacy. Previously, most patient doses were prepared as needed just before injection. Currently, to minimize repeated entries into the clean room, most patient doses are prepared in batches; that is, early morning and noontime preparation of doses to be injected at v...