background: in radiotherapy, wedge filters are used for optimizing the tumor dose distribution in patients. the attenuation in beam intensity due to the presence of wedge filter is compensated by means of a wedge factor measured at the central axis of the beam. the field size, depth and ssd dependence of wedge factor have been assessed for 9mv radiations of neptun pc linear accelerator. materials and methods: wedge factors (wf) at different ssd, field size (fs) and depth (d) in water were measured for 8 steel wedges with different sizes and angles of 15, 30, 45, and 60 degree. experimental data were obtained using neptun 10pc, linac 9mv x-ray machine, a 3d water phantom, dosimeters and an electrometer. to study the effect of field size on wf, the wedge factor was measured for square field sizes from 5 ´ 5 to 20 ´ 20 cm, with 1 cm increment intervals for all wedges and, at the depth of 10 cm, ssd of 100 cm with monitor unit (mu) of 80. effects of depth on wf were studied by measurement in various depths from 3-19cm for all wedge angles at ssd of 100cm, field size of 10 ´ 10cm and 80 mu irradiation. effects of ssd on wf were investigated by a variation of ssd from 90-110cm with 5cm increment intervals while the dosimeter was set at depth of 10cm and field size of 10 ´ 10cm were irradiated for 80mu. results: linear dependence of wf with field size and depth of measurements were confirmed with 95% certainty. shapiro-wilk test, showed that the residual data of the regression tests have normal distributions (p>0.05). there was also found no linear relationship between wf and ssd (p>0.05). conclusion: wf has linear dependence with field size and depth of measurements, but the rate of variations are less than 2.2% per 10cm variation in field size and less than 1.3% per 10 cm variation in depth of measurements, therefore, correction of wf for field size and depth of treatments in clinical trials is negligible. iran . j. radiat. res., 2004 2 (2): 53-58
منابع مشابه
Assessment of variation of wedge factor with depth, field size and SSD for Neptun 10PC Linac in Mashhad Imam Reza Hospital
Background: In radiotherapy, wedge filters are used for optimizing the tumor dose distribution in patients. The attenuation in beam intensity due to the presence of wedge filter is compensated by means of a wedge factor measured at the central axis of the beam. The field size, depth and SSD dependence of wedge factor have been assessed for 9MV radiations of Neptun PC linear accelerator. Materia...
متن کاملA Retrospective Study of Ectoparasitosis in Patients Referred to Imam Reza Hospital of Mashhad, Iran
This cross-sectional study was performed on all patients suspected to be suffering from ectoparasites who were referred to the parasitology laboratory of Imam Reza Hospital of Mashhad during 15 years (April 1995 to April 2010). All patients' data were collected from the questionnaires and then analyzed statistically. From 1814 suspected patients to be suffering from ectoparasites, 375 patients ...
متن کاملThe incidence of cross infections in Imam Reza hospital, Mashhad, Iran
BACKGROUND AND OBJECTIVES Cross Infections (CIs) are considered as a major public health problem worldwide. They cause delay in recovery, increased mortality and morbidity. The purpose of this study is to report the incidence of CIs in our teaching hospital during a 23-month period. MATERIALS AND METHODS In this descriptive cross-sectional study, 76766 patients from 2009 to 2011 admitted to 1...
متن کاملAssessment of surgical site infection risk factors at Imam Reza hospital, Mashhad, Iran between 2006 and 2011
BACKGROUND The present study was conducted to establish the patterns and risk factors of surgical site infections in our institution between 2006 and 2011. METHODS This was a retrospective cross-sectional study. The surgical site infection (SSI) was identified based on the presence of ICD-10-CM diagnostic code in hospital discharge records. By using a standardized data collection form predict...
متن کاملdiagnostic and developmental potentials of dynamic assessment for writing skill
این پایان نامه بدنبال بررسی کاربرد ارزیابی مستمر در یک محیط یادگیری زبان دوم از طریق طرح چهار سوال تحقیق زیر بود: (1) درک توانایی های فراگیران زمانیکه که از طریق برآورد عملکرد مستقل آنها امکان پذیر نباشد اما در طول جلسات ارزیابی مستمر مشخص شوند; (2) امکان تقویت توانایی های فراگیران از طریق ارزیابی مستمر; (3) سودمندی ارزیابی مستمر در هدایت آموزش فردی به سمتی که به منطقه ی تقریبی رشد افراد حساس ا...
15 صفحه اولQuality of bedside teaching in internal wards of Qaem and Imam Reza hospitals in Mashhad
BACKGROUND Bedside teaching is a patient-based teaching method in medical education. The present study has been conducted with the aim of investigating the quality of bedside teaching in the internal wards of Qaem and Imam Reza Educational Hospitals. METHODS This study follows a mixed qualitative-quantitative approach using checklists on educational clinical rounds in Imam Reza and Qaem Hospi...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of radiation researchجلد ۲، شماره ۲، صفحات ۵۳-۵۸
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023