the physical characteristics of a slic-epid for transmitted dosimetry

نویسندگان

m. mohammadi department of medical physics, royal adelaide hospital. adelaide, sa 5000, australia

e. bezak department of medical physics, royal adelaide hospital. adelaide, sa 5000, australia

چکیده

abstract background: for treatment verification in radiation therapy. several physical characteristics of scanningliquid filled ionization chamber epid (slic-epid) including: extra build-up layer,reproducibility and uniformity, and noise level were investigated.electronic portal imaging devices (epids) have found an outstanding positionmaterials and methods: equilibrium, 1-30 mm white water materials (rw3) were placed on the epid cover and thevariation of pixel values were investigated. to assess the short term reproducibility, a series of10 consecutive electronic portal images (epis) were acquired. the variation of pixel valueswere then determined in irradiated field using matlab software. for long term reproducibility,the described above experiment was then repeated seven times. to determine the noise levelin epid images, 10 consecutive flood images were acquired. the measurement was repeatedafter two days during a fortnight.to determine the extra build-up layer to reach the electronicresults: no significant variation was observed between the maximum thickness of build-up layerrequired for the central axis and peripheral points. for reproducibility measurements, no systematicvariation was observed between mean, maximum and minimum acquired pixel values.both the long-term and short term reproducibility was found to be less than 1%. the noise levelwas generally less than 1% and this can be referred as an acceptable dose level5 mm of rw3 material was found to increase the pixel values to the maximum possible..conclusion:can be used for dosimetry. however, for a particular linac energy and epid image acquisitionmode, the extra build-up layer thickness must be known for the epid to be used for dosimetricpurposesthe physical characteristics, measured in this work, suggest that the slic-epid. iran. j. radiat. res., 2005 2 (4): 175-183

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The physical characteristics of a SLIC-EPID for transmitted dosimetry

ABSTRACT Background: for treatment verification in radiation therapy. Several physical characteristics of ScanningLiquid filled Ionization Chamber EPID (SLIC-EPID) including: extra build-up layer,reproducibility and uniformity, and noise level were investigated.Electronic Portal Imaging Devices (EPIDs) have found an outstanding positionMaterials and Methods: equilibrium, 1-30 mm white water mat...

متن کامل

An Empirical Transmitted EPID Dosimetry Method using a Back-Projection Algorithm

Background: The present study aimed to introduce a rapid transmission dosimetry through an electronic portal-imaging device (EPID) to achieve two-dimensional (2D) dose distribution for homogenous environments. Material and Methods: In this Phantom study, first, the EPID calibration curve and correction coefficients for field size were obtained from EPID and ionization chamber. Second, the...

متن کامل

The impact of MLC transmitted radiation on EPID dosimetry for dynamic MLC beams.

The purpose of this study was to experimentally quantify the change in response of an amorphous silicon (a-Si) electronic portal imaging device (EPID) to dynamic multileaf collimator (dMLC) beams with varying MLC-transmitted dose components and incorporate the response into a commercial treatment planning system (TPS) EPID prediction model. A combination of uniform intensity dMLC beams and stat...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

EPID in vivo Dosimetry

Introduction: The most modern radiotherapy devices are equipped with an Electronic Portal Imaging Device (EPID) system which is located on opposite side of the machine’s head. EPID system is often used to setting up the position verification during or between radiotherapy sessions. Material and Methods: Various types of dosimeters have been used to setting up ...

متن کامل

EPID‐based dosimetry to verify IMRT planar dose distribution for the aS1200 EPID and FFF beams

We proposed to perform a basic dosimetry commissioning on a new imager sys-tem, the Varian aS1200 electronic portal imaging device (EPID) and TrueBeam 2.0 linear accelerator for flattened (FF) and flattening filter-free (FFF) beams, then to develop an image-based quality assurance (QA) model for verification of the system delivery accuracy for intensity-modulated radiation therapy (IMRT) treat-...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۲، شماره ۴، صفحات ۱۷۵-۱۸۳

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023