enhancement of md-55-2 radiochromic film sensitivity using a multilayer film technique for applications in the low dose range

نویسندگان

h. pourbeigi department of nuclear research center, atomic energy organization of iran, tehran, iran

a.s. meigooni department of radiation medicine, university of kentucky, usa

h. ghafourian department of nuclear research center, atomic energy organization of iran

r.a. koona department of radiation medicine, university of kentucky, usa

چکیده

abstractbackgrounds: md-55-2 is one of the radiochromic film models with the sensitivity suitable for dose measurements ranging from 5 to 100 gy.  however, this lower limit makes the film impractical for its applications in many areas such as brachytherapy source dosimetry.materials and methods: in this project, the useful range of the film has been extended by using a multilayer film technique. in this technique, single-, double-, and triple- layers of films were exposed to the doses ranging from 0.5 to 10 gy using a co-60 photon beam. calibration curves for corresponding layers of films were obtained with a spectrophotometer using a 680nm wavelength.results: the results indicated that the sensitivities of double and triple layers were approximately 200% and 300%, respectively, higher than a single-layer film.  the impact of multilayer film arrangement on the energy dependence of the md-55-2 radiochromic film has also been examined using 100kvp, 80 kvp, and 6 mv x-ray beams. the results indicated an insignificant (within 5%) change in film responses with the beam energy. conclusion: therefore, the multilayer technique enhances the radiochromic film sensitivity and expands its application to the low dose range in field of brachytherapy source dosimetry.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhancement of MD-55-2 radiochromic film sensitivity using a multilayer film technique for applications in the low dose range

 ABSTRACTBackgrounds: MD-55-2 is one of the Radiochromic film models with the sensitivity suitable for dose measurements ranging from 5 to 100 Gy.  However, this lower limit makes the film impractical for its applications in many areas such as brachytherapy source dosimetry.Materials and methods: In this project, the useful range of the film has been extended by using a multilayer film techniqu...

متن کامل

High sensitivity radiochromic film dose comparisons.

This short note investigates the dose characteristics of a relatively new high sensitivity radiochromic film (Gafchromic HS) and compares dose and energy response to various Gafchromic film types and radiographic (EDR-2) film. The original MD-55-1 and two improved sensitivity films, MD-55-2 and HS film, were investigated for energy and dose response. Results show that the energy response of the...

متن کامل

Measurement of gold nanofilm dose enhancement using unlaminated radiochromic film.

PURPOSE Bombarding high-Z material with x-ray radiation releases Auger electrons and Coster-Kronig electrons, along with deeper penetrating fluorescent x-rays and photoelectrons. The Auger and Coster-Kronig electron penetration distance is on the order of nanometers to micrometers in water or tissue, creating a large dose enhancement accompanied by a RBE greater than 1 at the cellular level. Th...

متن کامل

Reference dosimetry using radiochromic film

The objectives of this study are to identify and quantify factors that influence radiochromic film dose response and to determine whether such films are suitable for reference dosimetry. The influence of several parameters that may introduce systematic dose errors when performing reference dose measurements were investigated. The effect of the film storage temperature was determined by comparin...

متن کامل

dose response of irradiated xrct radiochromic film

– gafchromic xrct radiochromic film is a self developing high sensitivity radiochromic filmproduct which can be used for assessment of delivered radiation doses which could match applications suchas computed tomography (ct) dosimetry. the dose response of gafchromic xrct radiochromic film hasbeen measured with reflectance spectrophotometry and desktop scanners. the film automatically changescol...

متن کامل

Radiochromic Film Dosimetry

Published by the American Association of Physicists in Medicine DISCLAIMER: This publication is based on sources and information believed to be reliable, but the AAPM and the editors disclaim any warranty or liability based on or relating to the contents of this publication. The AAPM does not endorse any products, manufacturers, or suppliers. Nothing in this publication should be interpreted as...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۳، شماره ۱، صفحات ۱۱-۱۶

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023