the evaluation of minimum detectable phantom thickness change using a scanning liquid filled ion chamber epid dose response
نویسندگان
چکیده
abstractbackground: although electronic portal imaging devices (epids) have originally developed for positioning verification, they can also be used for dosimetric purposes. in the current work, the dose response of minimum detectable thickness of a scanning liquid filled ion chamber epid, slic-epid, and the variation of transmitted dose with the shift of inhomogeneity inside of phantom was also evaluated were investigated.materials and methods: the slic-epid pixel values were converted to the dose values using ionization chamber calibration and kodak extended dose range films (edr2 films). the variation of epid dose values with phantom thickness was investigated. in order to find the rate of dose deposited per centimetre of phantom, several reference points were defined and the variation of dose delivered to the points in the vicinity of reference points was investigated. two cm thick foam layer, as air gap, was shifted in the beam direction to evaluate the variation of transmitted dose with the shift of inhomogeneity position inside of phantom.results: an exponential decrease of the transmitted dose values was observed with the increase of the thickness of attenuators. the maximum and minimum rate of dose deposited per unit of phantom thickness was found to be 5.45% /cm and 3.78% /cm, respectively. due to the reproducibility and noise level of slic-epid, a 0.5 cm of thickness can be detected with a good reliability. the relative error of epid dose values increases with an increase of phantom thickness for both data sets. the relative error did not exceed 0.7%. no significant variation in transmitted dose inplane and crossplane profiles were found with the shift of inhomogeneity in the beam direction. conclusion: the minimum detectable thickness is an important factor to evaluate an imager for dosimetric purposes. the slic-epid can be used as a reliable two-dimensional dosimeter.
منابع مشابه
The evaluation of minimum detectable phantom thickness change using a scanning liquid filled ion chamber EPID dose response
ABSTRACTBackground: Although Electronic Portal imaging Devices (EPIDs) have originally developed for positioning verification, they can also be used for dosimetric purposes. In the current work, the dose response of minimum detectable thickness of a Scanning Liquid filled Ion Chamber EPID, SLIC-EPID, and the variation of transmitted dose with the shift of inhomogeneity inside of phantom was al...
متن کاملThe use of extended dose range film for dosimetric calibration of a scanning liquid‐filled ionization chamber electronic portal imaging device
A scanning liquid-filled ionization chamber electronic portal imaging device (SLIC-EPID) and extended dose range (EDR2) films were used to evaluate transmitted dose profiles for homogeneous and inhomogeneous phantoms. Calibrated ionization chamber measurements were used to convert the pixel values acquired from the electronic portal images to dose. Because SLIC-EPID was developed to have a unif...
متن کاملCharacterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy.
PURPOSE The purpose of the study is to investigate the characteristics of a two-dimensional (2D) liquid-filled ion chamber detector array, which is used for the verification of radiotherapy treatment plans that use small field sizes of up to 10 × 10 cm. METHODS The device used in this study was Octavius 1000 SRS model (PTW, Freiburg, Germany). Its 2D array of detectors consists of 977 liquid-...
متن کاملa synchronic and diachronic approach to the change route of address terms in the two recent centuries of persian language
terms of address as an important linguistics items provide valuable information about the interlocutors, their relationship and their circumstances. this study was done to investigate the change route of persian address terms in the two recent centuries including three historical periods of qajar, pahlavi and after the islamic revolution. data were extracted from a corpus consisting 24 novels w...
15 صفحه اولEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کاملDose-response characteristics of an amorphous silicon EPID.
Electronic portal imaging devices (EPIDs) were originally developed for the purpose of patient setup verification. Nowadays, they are increasingly used as dosimeters (e.g., for IMRT verification and linac-specific QA). A prerequisite for any clinical dosimetric application is a detailed understanding of the detector's dose-response behavior. The aim of this study is to investigate the dosimetri...