achievable accuracy in brain tumors by in vivo dosimetry with diode detectors

نویسندگان

m. allahverdi department of medical physics, cancer institute, tehran university of medical sciences, tehran, iran

m.r. taghizadeh department of radiotherapy, imam khomeini hospital, tehran university of medical sciences, tehran, iran

چکیده

abstract background: in vivo measurements of applied dose during radiotherapy treatment, is important to ensure accurate dose delivery to patients. uncertainty in dose delivery should fall within ±5% of the prescribed dose as recommended by icru. assessment of dose for radiotherapy applications performed with various types of detectors. in this study, semiconductor diodes were used which have some advantages for clinical dosimetry. materials and methods: the brain tumors have generally treated with two fields using ssd technique. entrance and exit dose were measured for each patient with diodes during treatment. entrance and exit dose measurements have converted to midline dose. measured entrance and exit doses have compared with calculated ones and large deviations (more than 5%) have observed. a farmer ionization chamber (0.6 cm) was used as the reference dose detector and a perspex water phantom (30 30cm2 area and thickness ranging from 5 cm to 30 cm) were used to determine calibration and correction factors. results: correction factors were determined and variations more than 1% have used to obtain correct doses. large deviations between measured and calculated for entrance (5.3%), exit (42%) and midline (47%) were detected. the difference was not found to be significant when comparing the measured entrance dose with the calculated one (p=0.696) and the measured exit dose with calculated one (p=0.643) and measured midline dose with calculated one (p=0.104). conclusion: in vivo dosimetry is very useful to check the dose delivered to the patient. a high precision obtained when the calibration and correction factors for each parameter of influence on the diode response are carefully determined and applied to convert the diode signal in the adsorbed dose. in this study, the target-absorbed doses were estimated from the measured entrance dose and the measured transmission.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Achievable accuracy in brain tumors by in vivo dosimetry with diode detectors

ABSTRACT Background: In vivo measurements of applied dose during radiotherapy treatment, is important to ensure accurate dose delivery to patients. Uncertainty in dose delivery should fall within ±5% of the prescribed dose as recommended by ICRU. Assessment of dose for radiotherapy applications performed with various types of detectors. In this study, semiconductor diodes were used which have s...

متن کامل

Verification of the Accuracy of the Delivered Dose in Brain Tumors by in Vivo Dosimetry Using Diode Detectors

Introduction: During radiotherapy, high accuracy in the dose delivery is required because there is a strong  relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. In  many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. In general,  the uncertainty in the dose delivered should fall within  ± 5% of the...

متن کامل

verification of the accuracy of the delivered dose in brain tumors by in vivo dosimetry using diode detectors

introduction: during radiotherapy, high accuracy in the dose delivery is required because there is a strong  relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. in  many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. in general,  the uncertainty in the dose delivered should fall within  ± 5% of the...

متن کامل

Entrance dose measurements for in‐vivo diode dosimetry: Comparison of correction factors for two types of commercial silicon diode detectors

Silicon diode dosimeters have been used routinely for in-vivo dosimetry. Despite their popularity, an appropriate implementation of an in-vivo dosimetry program using diode detectors remains a challenge for clinical physicists. One common approach is to relate the diode readout to the entrance dose, that is, dose to the reference depth of maximum dose such as d(max) for the 10x10 cm(2) field. V...

متن کامل

EPID in vivo Dosimetry

Introduction: The most modern radiotherapy devices are equipped with an Electronic Portal Imaging Device (EPID) system which is located on opposite side of the machine’s head. EPID system is often used to setting up the position verification during or between radiotherapy sessions. Material and Methods: Various types of dosimeters have been used to setting up ...

متن کامل

Verification of the Accuracy of the Delivered Dose in Pelvic and Breast Cancer Radiotherapy by in-vivo Semi-Conductor Dosimetry

Introduction: Delivering maximum dose to tumor and minimum dose to normal tissues is the most important goal in radiotherapy. According to ICRU, the maximum acceptable uncertainty in the delivered dose compared to the prescribed dose should be lower than 5%, and this is because of the relationship between absorbed dose, tumor control and normal tissue damage. Absorbed dose accuracy is investiga...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۳، شماره ۴، صفحات ۱۵۳-۱۶۱

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023