a study of densitometry comparison among three radiographic processing solutions

نویسندگان

v. changizi department of radiology technology, school of allied medical sciences, tehran university of medical sciences, tehran, iran

e. jazayeri department of radiology technology, school of allied medical sciences, tehran university of medical sciences, tehran, iran

a. talaeepour department of oral radiology, school of dentistry, tehran university of medical sciences, tehran, iran

چکیده

abstract background: the radiographic image accuracy depends on the x-ray film information visibility. good visibility is found by good contrast. radiation exposure parameters (kvp, mas) and film processing conditions have impact on contrast. in dentistry radiography machines, exposure time and processing procedure are set by radiographer. no optimized exposure time and processing conditions may lead to incorrect diagnosis and re-exposure of the patient. therefore, we studied the performance of the three different available processing solutions with dental x-ray film. materials and methods: dental intraoral e-speed films, size 2 (kodak company, usa) were used in this study. these films were developed in a manual processor using three different brands of processing solution: 1) taifsaz (iran), 2) darutasvir (iran) and 3) agfa (germany) for temperatures of 25oc, 28oc and 30oc at the three different exposure times, 0.2 s, 0.25 s and 0.35 s. performance was evaluated with respect to base plus fog, relative contrast and relative speed. results: darutasvir processing solution as the cheapest one showed higher base plus fog density at 25oc and 30oc than that of taifsaz and agfa solutions. also, darutasvir solution was found to have better relative contrast than that of the others, except for 30oc at 0.25 s. relative speed was higher in darutsavir solution than agfa for 25oc at three exposure times used in this study, for 28oc at 0.2 s and for 30oc at 0.35 s. taifsaz processing solution was in the second order with respect to tested conditions. conclusion: comparison among available x-ray film processing solutions for different temperatures at different exposure times can help to maintain image quality while patient exposure and film cost are kept considerably low.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A study of densitometry comparison among three radiographic processing solutions

ABSTRACT Background: The radiographic image accuracy depends on the X-ray film information visibility. Good visibility is found by good contrast. Radiation exposure parameters (kVp, mAs) and film processing conditions have impact on contrast. In dentistry radiography machines, exposure time and processing procedure are set by radiographer. No optimized exposure time and process...

متن کامل

a comparative study of subtitled vs auditory documentaries comprehension among persian speakers of english

abstract this study set out to compare the effect of modality of presentation (subtitled vs. auditory) in the comprehension of verbal content of documentary films among iranian efl students. to this end, (30 male 30 female) students were chosen from two schools. after their homogeneity was established, the students attended the listening sessions to watch five documentary films over t...

15 صفحه اول

a comparative study of the theme of "marriage" in three victorian novelists: charles dickens, george eliot and thomas hardy

این تحقیق کوشیده است با انتخاب پنج رمان از میان آثار برگزیده، «چارلز دیکنز»، «جورج الیوت» و «توماس هاردی » و با رویکردی تطبیقی به بررسی درونمایه ی «ازدواج» در آثار این سه رمان نویس بزرگ دوره ی ویکتوریا بپردازد. فرضیه ی اولیه ی تحقیق این بوده است که چارلز دیکنز (1870- 1812) با زبانی شوخ و گزنده، جورج الیوت(1880- 1819) با نگاهی آموزشی–اندرزگونه و توماس هاردی(1928- 1840) با رویکردی تلخ وانتقادی به...

evaluation sensitometric properties of radiographic films at different processing solutions

the aim of this study is to compare the sensitometric properties of commonly used radiographic films processed with chemical solutions in different workload hospitals. the effect of different processing conditions on induced densities on radiologic films was investigated. two accessible double emulsions fuji and kodak films were exposed with 11-step wedge and processed with champion and cpac pr...

متن کامل

a comparison of radiographic film densitometry using a new computerized tool with a digital densitometer

objectives: the purpose of this study was to develop and test a new tool for radiographic densitometry by combining periapical films and aluminum step wedge. materials and methods: we reviewed 50 kodak e-speed intraoral films. an aluminum step wedge consisting of 16 steps was constructed. each step was 1mmx3mx10mm. the step wedge was exposed to varying exposure times, ranging from 0.05 second t...

متن کامل

A Comparison of Radiographic Film Densitometry Using a New Computerized Tool with a Digital Densitometer

OBJECTIVES The purpose of this study was to develop and test a new tool for radiographic densitometry by combining periapical films and aluminum step wedge. MATERIALS AND METHODS We reviewed 50 Kodak E-speed intraoral films. An aluminum step wedge consisting of 16 steps was constructed. Each step was 1mm×3m×10mm. The step wedge was exposed to varying exposure times, ranging from 0.05 second t...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۴، شماره ۲، صفحات ۸۱-۸۶

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023