a new approach for quantitative evaluation of reconstruction algorithms in spect

نویسندگان

e. raeisi department. of medical physics, tarbiat modares university, tehran, iran

h. rajabi department. of medical physics, tarbiat modares university, tehran, iran

s.m.r. aghamiri division of radiation medicine, shahid beheshti university, tehran, iran

چکیده

abtract background: in nuclear medicine, phantoms are mainly used to evaluate the overall performance of the imaging systems and practically there is no phantom exclusively designed for the evaluation of the software performance.  in this study the hoffman brain phantom was used for quantitative evaluation of reconstruction techniques. the phantom is modified to acquire tomographic and planar image of the same structure. the planar image may be used as the reference image to evaluate the quality of reconstructed slices using the companion software developed in matlab. methods and materials: the designed phantom is composed of 4 independent 2d slices that may be placed juxtapose to form the 3d phantom. each slice is composed of objects of different size and shape e.g. circle, triangle, and rectangle. each 2d slice was imaged at the distances from 0 to 15 cm from the collimator surface. the phantom in 3d configuration was imaged acquiring 128 views of 128×128 matrix size. reconstruction was performed using different filtering condition and the reconstructed images were compared to the corresponding planar images. the modulation transfer function, scatter fraction and attenuation map were calculated for each reconstructed image results: since all the parameters of the acquisition were identical for the 2d and the 3d imaging. it was assumed that the difference in the quality of the images was exclusively due to reconstruction condition. the planar images were assumed to be the most perfect images that could be obtained with the system. comparing the reconstructed slices to the corresponding planar images yielded the optimum reconstruction condition.  the results clearly showed that wiener filter yields superior quality image among the entire filter tested. the extent of the improvement has been quantified in terms of universal image quality index. conclusion: the phantom and the accompanying software were evaluated and found to be quite useful in determining the optimum filtering condition and mathematical evaluation of the scatter and attenuation in tomographic images.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Approach for Quantitative Evaluation of Reconstruction Algorithms in SPECT

ABTRACT Background: In nuclear medicine, phantoms are mainly used to evaluate the overall performance of the imaging systems and practically there is no phantom exclusively designed for the evaluation of the software performance.  In this study the Hoffman brain phantom was used for quantitative evaluation of reconstruction techniques. The phantom is modified to acquire t...

متن کامل

Development and Evaluation of Image Reconstruction Algorithms for a Novel Desktop SPECT System

Objective (s): Various iterative reconstruction algorithms in nuclear medicine have been introduced in the last three decades. For each new imaging system, it is wise to select appropriate image reconstruction algorithms and evaluate their performance. In this study, three approaches of image reconstruction were developed for a novel desktop open-gantry SPECT system, PERSPECT, to assess their p...

متن کامل

a new approach to credibility premium for zero-inflated poisson models for panel data

هدف اصلی از این تحقیق به دست آوردن و مقایسه حق بیمه باورمندی در مدل های شمارشی گزارش نشده برای داده های طولی می باشد. در این تحقیق حق بیمه های پبش گویی بر اساس توابع ضرر مربع خطا و نمایی محاسبه شده و با هم مقایسه می شود. تمایل به گرفتن پاداش و جایزه یکی از دلایل مهم برای گزارش ندادن تصادفات می باشد و افراد برای استفاده از تخفیف اغلب از گزارش تصادفات با هزینه پائین خودداری می کنند، در این تحقیق ...

15 صفحه اول

Performance Evaluation of FBP Reconstruction in SPECT Imaging

Introduction:  The  purpose  of  this  study  is  to  define  the  optimal  parameters  for  the  tomographic  reconstruction procedure in a routine single photon emission tomography. The Hoffman brain phantom  is modified to evaluate the reconstruction method. The phantom was imaged in a 3 and 2-dimensional  conformation and the results were compared.   Materials  and  Methods:  The  2D  phant...

متن کامل

A NEW APPROACH FOR EVALUATION OF SEISMIC SLOPE PERFORMANCE

The evaluation of seismic slope performance during earthquakes is important, because the failure of slope (such as an earth dam, natural slope, or constructed earth embankment) can result in significant financial losses and human. It is important, therefore, to be able to forecast such displacements induced by earthquake. However, the traditional forecasting methods, such as empirical formulae,...

متن کامل

A new approach for performance evaluation of energy-related enterprises

Oil is among the most effective and the largest industries in the world. Given that it supplies a large percentage of the world’s energy and plays a significant role in the national power and international credit of countries, it has a huge impact on our world today. Iran has  huge oil reserves, and plays a key role in the exchange of the required energy in the world. In order to improve the pe...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۴، شماره ۲، صفحات ۷۷-۸۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023