60co γ-ray attenuation coefficient of barite concrete

نویسندگان

f. bouzarjomehri department of medical physics, shahid sadoghi university of medical sciences, yazd, iran

t. bayat department of medical physics, centre for education and training, zanjan, iran

m.h. dashti r department of physiology, shahid sadoghi university of medical sciences, yazd, iran

j. ghisari department of physics, yazd university, yazd, iran

چکیده

abstract  introduction: recently uses of medium and high energy x-rays has been increased in iran and radiotherapy centers along with a variety of accelerators have been installed in some provinces. in the other hand there is no sufficient skill in designing and making radiotherapy treatment rooms. this study was conducted to evaluate the efficacy of different mixtures of barite concrete for shielding the radiotherapy rooms. in this way we emphasized on determining the size and amount of barite aggregations to achieve the maximum radiation attenuation which leads to minimizing wall thickness in treatment room. materials and methods: to increase concrete density, the barite aggregation was added to concrete. different size variations of barite aggregates mixed with different water/cement ratio were examined. the dimension of cubic concrete specimens for compression strength test was 15×15×15 cm. the rectangular barite concrete blocks with different compressions as used for strength test with cross section of 10×10 cm and thicknesses from 5 to 40 cm were used for radiation attenuation test. for this test concrete specimens were irradiated by gamma beam of 60co (phoenix theratron). the transmission radiation through the blocks was measured by a farmer ionization chamber (fc65p) in yazd radiotherapy center. results: our findings showed that in all specimens the highest mean compression strength was related to the specimens with equal ratio of fine to coarse barite aggregates but the lowest hvl was obtained from mixtures with fine to coarse ratio of 35/65. the concrete sample with a 0.45 water/cement ratio, 350 kg/m3 cement and equal amounts of fine and coarse barite sands had nearly minimum half value layer(hvl) and maximum compression strength, so this sample was considered as the best barite concrete sample. conclusion: since hvl of the barite concrete specimens with the same compression strength is markedly lower than the conventional concrete and we have a plenty barite mines in our country it is recommended to use barite concrete with the best mixture condition based on our findings for shielding the radiotherapy rooms.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

60Co γ-ray attenuation coefficient of barite concrete

ABSTRACT  Introduction: Recently uses of medium and high energy x-rays has been increased in Iran and radiotherapy centers along with a variety of accelerators have been installed in some provinces. In the other hand there is no sufficient skill in designing and making radiotherapy treatment rooms. This study was conducted to evaluate the efficacy of different m...

متن کامل

Chemical corrosion on gamma-ray attenuation properties of barite concrete

osting by E Abstract The variation of photon attenuation coefficient on the chemical media has been investigated. For this purposes the linear attenuations of barite concrete have been measured at 662, 1773 and 1332 keV before leaving the chemical media and following a 6 month period. The linear attenuation coefficients have been measured using gamma spectrometer that contains a NaI(Tl) detecto...

متن کامل

X-ray mass attenuation coefficient of silicon: theory versus experiment.

We compare new experimental x-ray total mass attenuation coefficients of silicon obtained with the x-ray extended-range technique (XERT) from 5 to 20 keV with theoretical calculations and earlier experimental measurements over a 5 to 50 keV energy range. The accuracy of between 0.27% and 0.5% of the XERT data allows us to probe alternate atomic and solid state wave function calculations and to ...

متن کامل

The Effect of 5′-Adenylic Acid on Hepatic Proteome of Mice Radiated by 60Co γ-ray

Understanding the protection mechanism of 5'-AMP requires comprehensive knowledge of the proteins expressed during the period that the body is exposed to irradiation. Proteomics provides the tools for such analyses. Here, the experimental ICR mice were divided into three groups (normal group, model group and 5'-AMP + irradiation group). After different treatment, the hepatic total protein of ea...

متن کامل

100 Gy 60Co γ-Ray Induced Novel Mutations in Tetraploid Wheat

10 accessions of tetraploid wheat were radiated with 100 Gy (60)Co γ -ray. The germination energy, germination rate, special characters (secondary tillering, stalk with wax powder, and dwarf), meiotic process, and high-molecular-weight glutenin subunits (HMW-GSs) were observed. Different species has different radiation sensibility. With 1 seed germinated (5%), T. dicoccum (PI434999) is the most...

متن کامل

Behavioral, Morphological, and Gene Expression Changes Induced by 60Co-γ Ray Irradiation in Bactrocera tau (Walker)

The sterile insect technique (SIT) may reduce pest populations by allowing sufficient amount of irradiation-induced sterile males to mate with wild females whilst maintaining mating ability comparable to wild males. Although the SIT methods are well understood, the optimal sterilizing dose and processing development stage for application vary among species. To ensure effective pest control prog...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۴، شماره ۲، صفحات ۷۱-۷۵

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023