planar and spect monte carlo acceleration using a variance reduction technique in i131 imaging
نویسندگان
چکیده
background: various variance reduction techniques such as forced detection (fd) have been implemented in monte carlo (mc) simulation of nuclear medicine in an effort to decrease the simulation time while keeping accuracy. however most of these techniques still result in very long mc simulation times for being implemented into routine use. materials and methods: convolution-based forced detection (cfd) method as a variance reduction technique was implemented into the well known simind mc photon simulation software. a variety of simulations including point and extended sources in uniform and non-uniform attenuation media, were performed to compare differences between fd and cfd versions of simind modeling for i131 radionuclide and camera configurations. experimental measurement of system response function was compared to fd and cfd simulation data. results: different simulations using the cfd method agree very well with experimental measurements as well as fd version. cfd simulations of system response function and larger sources in uniform and non-uniform attenuated phantoms also agree well with fd version of simind. conclusion: cfd has been modeled into the simind mc program and validated. with the current implementation of cfd, simulation times were approximately 10-15 times shorter with similar accuracy and image quality compared with fd mc. iran. j. radiat. res., 2007 4 (4): 175-182
منابع مشابه
Planar and SPECT Monte Carlo acceleration using a variance reduction technique in I131 imaging
Background: Various variance reduction techniques such as forced detection (FD) have been implemented in Monte Carlo (MC) simulation of nuclear medicine in an effort to decrease the simulation time while keeping accuracy. However most of these techniques still result in very long MC simulation times for being implemented into routine use. Materials and Methods: Convolution-based force...
متن کاملOptimization of a SPECT system for imaging of 90Y in liver using Monte Carlo method
Introduction: Acquiring a high quality image has assigned an important concern for obtaining accurate diagnosis in nuclear medicine. Detector and collimator are critical component of Single Photon Emission Computed Tomography (SPECT) imaging system for giving accurate information from exact pattern of radionuclide distribution in the target organ. The images are strongly affect...
متن کاملAbsorbed dose of Fetus in SPECT-CT Imaging of Mother's Abdomen Regions using Monte Carlo method
SPECT-CT is an imaging method for diagnosing diseases and studying physiology of the body. In this type of imaging, due to the use of radiopharmaceutical for imaging (SPECT) and X-rays (CT), a relatively high dose of radiation is introduced into the patient. If the patient is pregnant, considering that the developing fetus is sensitive to any radiation in the uterus throughout the entire period...
متن کاملVariance Reduction Techniques in Monte Carlo Methods
Monte Carlo methods are simulation algorithms to estimate a numerical quantity in a statistical model of a real system. These algorithms are executed by computer programs. Variance reduction techniques (VRT) are needed, even though computer speed has been increasing dramatically, ever since the introduction of computers. This increased computer power has stimulated simulation analysts to develo...
متن کاملVariance Reduction in Monte-Carlo Tree Search
Monte-Carlo Tree Search (MCTS) has proven to be a powerful, generic planning technique for decision-making in single-agent and adversarial environments. The stochastic nature of the Monte-Carlo simulations introduces errors in the value estimates, both in terms of bias and variance. Whilst reducing bias (typically through the addition of domain knowledge) has been studied in the MCTS literature...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of radiation researchجلد ۴، شماره ۴، صفحات ۱۷۵-۱۸۲
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023