background: several landmine detection methods, based on nuclear techniques, have been suggested up to now. neutron-induced gamma emission, neutron and gamma attenuation, and fast neutron backscattering are the nuclear methods used for landmine detection. in this paper an optimized (safe and effective) moderating structure using an 241am-be neutron source for detecting landmines has been investigated by experiment and mcnp simulation. materials and methods: the experimental set up was composed of a lead (pb) cylindrical shell enclosing the neutron source, embedded in a fixed size high-density polyethylene (hdpe) cylinder with the variable thickness of the upper and lower moderator/reflector. some experimental groups were used to measure several moderator configurations' responses by replacing a thermal neutron detector with the mine and counting the neutron capture events. results: the total experimental results led to the introduction of optimum moderator geometry for landmine detection. a safe landmine detection system was obtained which enabled the operator to use it for 950 h/year, regarding the dose limit recommended by icrp. conclusion: the novel method for optimization applied in this work is more applicable than the usual approach that is based on measuring the prompt gamma rays emitted by the landmine. results showed that the method can be optimized in short time, without the usual difficulties of the other methods.
منابع مشابه
The safety of a landmine detection system using graphite and polyethylene moderator
Background: Several landmine detection methods, based on nuclear techniques, have been suggested up to now. Neutron-induced gamma emission, neutron and gamma attenuation, and fast neutron backscattering are the nuclear methods used for landmine detection. In this paper an optimized (safe and effective) moderating structure using an 241Am-Be neutron source for detecting landmines has been invest...
متن کاملAn Optimum Landmine Detection System Using Polyethylene Moderator and 241Am-Be as a Neutron Source
In this paper an optimized moderating structure using an 241Am-Be neutron source for detecting landmines (using the PGNAA method) has been investigated by experiment. The experimental set up composed of a Pb cylindrical shell enclosing the neutron source, embedded in a fixed size High-density polyethylene (HDPe) cylinder with the variable thickness of the upper and lower moderator. The optimizi...
متن کاملLandmine Detection Using Radar
Landmines are affecting the lives and livelihood of millions of people around the world. The video impulse ground penetrating radar system for detection for small and shallow buried objects has been developed. The hardware combines commercially available components with components specially developed or modified for being used in the system. The GPR system has been desired to measure accurately...
متن کاملon the relationship between using discourse markers and the quality of expository and argumentative academic writing of iranian english majors
the aim of the present study was to investigate the frequency and the type of discourse markers used in the argumentative and expository writings of iranian efl learners and the differences between these text features in the two essay genres. the study also aimed at examining the influence of the use of discourse markers on the participants’ writing quality. to this end the discourse markers us...
15 صفحه اولمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of radiation researchجلد ۵، شماره ۳، صفحات ۱۳۷-۱۴۲
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023