diode calibration for dose determination in total body irradiation
نویسندگان
چکیده
background: total body irradiation (tbi) is different from standard radiotherapy in many aspects, so it is not easy to predict the delivered dose to the patient under tbi treatment. diode dosimetry procedures for surface dose reading can help to define variations of the actually delivered dose from the prescribed one. the aim of this study was to describe the measurements made to calibrate diodes in order to implement as a dosimeter for tbi tratment. an algorithm was also proposed based on diode dosimetry in order to determine the midplane dose. materials and methods: in this study, four p-type diodes connected to a multidose electrometer were implemented as dosimeter. for diode calibration a water phantom with dimension of 30×30×32cm3 along with a 0.6 cc farmer ion chamber were used. directional dependence of diodes, the effects of thickness correction factor and complete backscatter factor were studied. three algorithms, arithmetic, geometric mean and proposed algorithm were used to investigate midplane dose determination in tbi condition. results: it was found by measurements that the effect of angle incident on diode response was significant and should have been taken into account. variation in thickness correction factor was found about 0.7%. the accuracy in midplane dose determination in the arithmetic, geometric mean and proposed algorithm was about 3.8, 12.5 and 3.3%, respectively. conclusion: diode dosimetry is very useful as a check of midplane dose delivered to patients under tbi treatment. when the calibration and correction factors are carefully determined, high precision can be obtained. the proposed algorithm by this study seems to be useful in order to midplane dose determination in tbi condition. iran. j. radiat. res., 2008 6 (1): 43-50
منابع مشابه
Diode calibration for dose determination in total body irradiation
Background: Total Body Irradiation (TBI) is different from standard radiotherapy in many aspects, so it is not easy to predict the delivered dose to the patient under TBI treatment. Diode dosimetry procedures for surface dose reading can help to define variations of the actually delivered dose from the prescribed one. The aim of this study was to describe the measurements made to calib...
متن کامل3D heterogeneous dose distributions for total body irradiation patients
One major objective of total body irradiation (TBI) treatments is to deliver a uniform dose in the entire body of the patient. Looking at 3D dose distributions for constant speed (CstSpeed) and variable speed (VarSpeed) translating couch TBI treatments, dose uniformity and the effect of body heterogeneities were evaluated. This study was based on retrospective dose calculations of 10 patients t...
متن کاملFabrication of anthropomorphic phantoms for use in total body photon irradiation and total skin electron irradiation studies
Introduction: Total Skin Electron Therapy (TSET) and Total Body Irradiation (TBI) are kinds of treatment which use electron and photon beams to treat special types of cancers. The aim of these techniques are to deliver uniform dose to the entire skin while minimizing delivered dose to organs at risk. To check the homogeneity of dose delivery in TBI and TSET, using a humanoid ph...
متن کاملTotal body irradiation for myelomatosis.
In the first myeloma trial of the M.R.C. working party on leukaemia in adults the deaths that have occurred can be attributed to unrelated diseases (5%h-for example, cosonary thrombosis, etc.); causes indirectly telated to the tumour (80,for example, pneumonia due to the immune paresis); no obvious response of the tumour to treatment (27/); and finally relapse of the tumour after an initial res...
متن کاملTotal body irradiation dose optimization based on radiological depth
We have previously demonstrated the use of Eclipse fluence optimization to define aperture sizes for a novel aperture modulated translating bed total body irradiation (TBI) technique. The purposes of the present study were to identify, characterize, and correct for sources of error inherent in our previous fluence optimization technique, and to develop a clinically viable fluence optimization m...
متن کاملWaldenstrom’s Macroglobulinemia treated with fractionated low-dose total body irradiation
Case Report: A 78-year-old male with relapsed Waldenstrom’s macroglobulinemia following therapy with chlorambucil underwent a five-week course of TBI. The total dose delivered was 1.5 Gy, given as 0.15 Gy twice weekly for ten sessions. During the course of therapy his CD4 cells increased from 637 (cells/mm3) to 808 partly through treatment and then declined to 654 at the completion of therapy. ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of radiation researchجلد ۶، شماره ۱، صفحات ۴۳-۵۰
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023