evaluation of the relation between breast glandular absorbed dose and radiographic quality in mammography
نویسندگان
چکیده
background: breast is one of the main radiological sensitive organs, hence it is important to evaluate absorbed dose to this organ especially to the glandular parts. it is the aim of this study to measure mean glandular dose and image contrast in terms of different mammographic parameters. materials and methods: in this study two mammography machines located at said-al shohada (giotto) and shahid behesti (ge) hospitals were used. according to the recommendations of acr and mqsa, breast phantoms were constructed and used for this study. for dose evaluation tld dosimetry method was used. the tld dosimeters were of lif type and the reader was a solaro tld reader. results: to obtain a constant contrast when increasing kvp from 22 to 24, it was necessary to reduce mas by 12 percent. the obtained relation between these two parameters is: contrast=0.2829d-0.2427. it was also found that there is a linear relationship between contrast and image quality. the relation between these two parameters is: image quality = 28.117 contarst + 20.134. increasing kvp and hence decreasing mas results a reduction to the glandular dose, especially in patients with large breast. increasing kvp from 28 to 30 results in reduction of dose from 6.8mgy to 5mgy. conclusions: it was found that there has been a linear relationship between contrast and image quality. it was also found that increasing kvp necessitate to reduce mas for a constant contrast and hence reduction of glandular dose.
منابع مشابه
Evaluation of the relation between breast glandular absorbed dose and radiographic quality in mammography
Background: Breast is one of the main radiological sensitive organs, hence it is important to evaluate absorbed dose to this organ especially to the glandular parts. It is the aim of this study to measure mean glandular dose and image contrast in terms of different mammographic parameters. Materials and Methods: In this study two mammography machines located at Said-al Shohada (Giotto) ...
متن کاملEvaluation of the relation between breast glandular absorbed dose and radiographic quality in mammography
*Corresponding Author: Dr. Mohammad Bagher Tavakoli, Department of Medical Physics and Medical Engineering, Isfahan University of Medical Sciences, Isfahan, Iran. Fax: +98 311 7922412 E-mail: [email protected] Background: Breast is one of the main radiological sensitive organs, hence it is important to evaluate absorbed dose to this organ especially to the glandular parts. It is the aim of t...
متن کاملEvaluation of glandular dose in mammography in the presence of breast cyst using Monte Carlo simulation
Introduction: Average glandular dose (AGD), entrance skin air kerma (ESAK) and normalized glandular dose (DgN) are the main dosimetric quantities in mammography. In this study, DgN is evaluated in the presence of breast cyst, which is a common disease among women and the influence of size, number and location of the cysts on the DgN is investigated. Materials and Meth...
متن کاملthe investigation of the relationship between type a and type b personalities and quality of translation
چکیده ندارد.
on the relationship between using discourse markers and the quality of expository and argumentative academic writing of iranian english majors
the aim of the present study was to investigate the frequency and the type of discourse markers used in the argumentative and expository writings of iranian efl learners and the differences between these text features in the two essay genres. the study also aimed at examining the influence of the use of discourse markers on the participants’ writing quality. to this end the discourse markers us...
15 صفحه اولQuality Assurance and Average Glandular dose Measurement in Mammography Units
To ensure the safe operation of mammography units, acceptance tests and quality assurance (QA) protocols have been developed by the American Association of Physicists in Medicine (AAPM), Engineers Registration Board, and International Atomic Energy Agency. Eight mammography units manufactured by five different manufacturers located in hospitals in our region were investigated following the AAPM...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of radiation researchجلد ۶، شماره ۲، صفحات ۷۷-۸۲
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023