determining rectal dose through cervix cancer radiotherapy by 9 mv photon beam using tld and xr type t gafchromic® film
نویسندگان
چکیده
background: the goals of the present research were to investigate the rectal dose during four chosen techniques of cervical cancer radiotherapy and to examine how accurately the treatment planning represents dose measurements, and it’s practicality for routine use as well as, to determine the homogeneity of dose in tumor volume. materials and methods: the study was carried out using a nepton 10-pc unit and a rando phantom. the equipments which were used for dose determination were a radiochromic densitometer with gafchromic® film (xr type t), and a thermo-luminescent dosimeter (tld) reader system with tld chips for rectal and target volume dose determination. several techniques of external beam radiation therapy such as two-field (ap-pa), three-field and four-field with equal tumor dose and with equal applied dose were planned. results: the maximum dose received by rectum was caused by two-field technique. the results of two dosimetry types were compared with each other as well as with the treatment planning, however, no statistically significant difference was observed between them (p > 0.05). in three-field, four -field with equal tumor dose and four-field with equal applied dose, rectal dose was lower, respectively 26.17%, 33.75% and 16.47%, than tumor dose. conclusion: this study showed that dosimetry using tld and film during radiotherapy could have a useful role as a predictor of choosing appropriate technique for preventing future rectal complications. dose limitation to the rectum could possibly be achieved by using three-field and four-field techniques with equal tumor dose while maintaining a high dose to the tumor. iran. j. radiat. res., 2008 6 (3): 129-134
منابع مشابه
Determining rectal dose through cervix cancer radiotherapy by 9 MV photon beam using TLD and XR type T GAFCHROMIC® Film
Background: The goals of the present research were to investigate the rectal dose during four chosen techniques of cervical cancer radiotherapy and to examine how accurately the treatment planning represents dose measurements, and it’s practicality for routine use as well as, to determine the homogeneity of dose in tumor volume. Materials and Methods: The study was carried out using a Nepton 10...
متن کاملMeasurement of dose‐area product with GafChromic XR Type R film
Many of the newer X-ray machines are equipped with electronic means to provide dose-area product (DAP) information. For machines without that ability, an alternative method is to record radiation on a film that can handle a large amount of cumulative exposure. The use of GafChromic XR Type R film was investigated for this purpose by placing it at the X-ray tube assembly to record the radiation ...
متن کاملDosimetric evaluation of GAFCHROMIC® XR type T and XR type R films
The high spatial resolution of radiochromic film makes it ideal for dosimetric measurements and dose distributions in regions of high dose gradient. Intensity-modulated radiation therapy, intravascular brachytherapy, and eye-plaque radiation therapy demand precise spatial dosimetric calculations. Such precision is not possible with conventional dosimeters, such as thermoluminescent dosimeters a...
متن کاملIn vivo dosimetry of intraoral stent using TLD during external photon beam radiotherapy of oral cavity
Introduction: Individual oral stent is a mouth-opening device that used in head and neck cancer radiotherapy with the intention of decreasing radiation dose to health tissues. The aim of this study was to check the dose delivered to both the hard palate and tongue when patient uses the stent during radiotherapy of tongue carcinoma. Methods and materials<stron...
متن کاملAn Assessment of Spinal Cord Dose Following Radiotherapy of Nasopharyngeal Cancer by TLD and Rando Phantom
Introduction: Nasopharyngeal carcinoma is one of the most common malignancies in the head and neck region and radiotherapy is its treatment of choice. In spite of the fact that it is widely used, due to the presence of many sensitive organs or tissues in this region, patients may suffer from a wide range of side effects. One such sensitive tissue is the spinal cord. If the absorbed dose to spin...
متن کاملGafChromic XR‐QA film in testing panoramic dental radiography
The location and field size of the incident X-ray beam in panoramic dental radiography cannot be ascertained visually most of the time. However, these parameters are needed for quality control and dosimetry determination. To alleviate this problem, we tested GafChromic XR-QA film on two panoramic systems. For each system, we used the length of a cross-sectional image of the incident beam and th...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of radiation researchجلد ۶، شماره ۳، صفحات ۱۲۹-۱۳۴
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023