comparison of dosimetry parameters of two commercially available iodine brachytherapy seeds using monte carlo calculations
نویسندگان
چکیده
background: iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. dosimetric parameters of brachytherapy sources should be determined according to aapm tg-43u1 recommendations before clinical use. monte carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. materials and methods: dosimetric parameters (dose rate constant, radial dose function, and anisotropy function) of two i-125 brachytherapy sources (models ls-1 and intersource) were calculated with mcnp4c monte carlo code following task group #43 (tg-43u1) recommendations of american assossiation of physicists in medicine. the simulations were done inside a spherical water phantom because of its tissue equivalent properties. the monte carlo simulations for radial dose function were performed at distances ranging from 0.25 to 10 cm from the source center. the anisotropy functions f(r, θ), for both sources, were calculated at distances of 1, 2, 3, 5 and 7 cm from the source center for angles ranging from 15 to 90 degree. results: the results of the monte carlo simulation indicated a dose rate constant of 0.952 cgyh -1u-1 and 0.986 cgyh -1u-1 for models ls-1 and intersource, respectively. the tabulated data and fifth order polynomial coefficients for radial dose functions along the source are described in this paper. the results indicated that the anisotropy in dose distribution increased along the source axis. conclusion: the obtained results were in good agreement with measurements and calculations of other investigators, using other monte carlo codes. iran. j. radiat. res., 2010 7 (4): 217-222
منابع مشابه
Comparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations
Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...
متن کاملDosimetry of 188Re and 186Re sources based on Monte Carlo calculations for endovascular brachytherapy after balloon angioplasty
Background: Recent pre-clinical and clinical studies indicate that irradiation in the dose range of 15 to 30 Gy can reduce rate of restenosis in patients who have undergone an angioplasty. The use of filled balloon with radioactive solution was proposed as one of the possible intravascular irradiation techniques. Materials and Methods: The Monte Carlo N-particle Transport Code (MCNP4b) was used...
متن کاملA Comparison of the Dosimetric Parameters of Cs-137 Brachytherapy Source in Different Tissues with Water Using Monte Carlo Simulation
Introduction After the publication of Task Group number 43 dose calculation formalism by the American Association of Physicists in Medicine (AAPM), this method has been known as the most common dose calculation method in brachytherapy treatment planning. In this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...
متن کاملBayesian internal dosimetry calculations using Markov Chain Monte Carlo.
A new numerical method for solving the inverse problem of internal dosimetry is described. The new method uses Markov Chain Monte Carlo and the Metropolis algorithm. Multiple intake amounts, biokinetic types, and times of intake are determined from bioassay data by integrating over the Bayesian posterior distribution. The method appears definitive, but its application requires a large amount of...
متن کاملThermoluminescent and Monte Carlo dosimetry of IR06‐P103d brachytherapy source
This work presents experimental dosimetry results for a new 103Pd brachytherapy seed, in accordance with the AAPM TG-43U1 recommendation that all new low-energy interstitial brachytherapy seeds should undergo one Monte Carlo (MC) and at least one experimental dosimetry characterization. Measurements were performed using TLD-GR200A circular chip dosimeters using standard methods employing thermo...
متن کاملMonte Carlo dosimetry of a new 90Y brachytherapy source
PURPOSE In this study, we attempted to obtain full dosimetric data for a new (90)Y brachytherapy source developed by the College of Chemistry (Sichuan University) for use in high-dose-rate after-loading systems. MATERIAL AND METHODS The dosimetric data for this new source were used as required by the dose calculation formalisms proposed by the AAPM Task Group 60 and Task Group 149. The active...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of radiation researchجلد ۷، شماره ۴، صفحات ۲۱۷-۲۲۲
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023