background: proton induced x-ray emission (pixe) has been applied as reliable and improved techniques in this study to compare concentration of various trace elements in normal and abnormal varicose veins. materials and methods: five samples from normal veins and 13 samples from varicose veins bombarded by 2.0 mev energy proton beams produced by a van de graff accelerator in vacuum. two specimens from each sample, approximately 1cm, were processed for pixe (proton induced x-ray emission) analysis. both qualitative and quantitative analyses of potassium, iron, copper and zinc concentration were performed with respect to calcium concentration. results: the concentration of potassium and iron in the varicose vein group has been significantly higher than the normal group. copper and zinc concentration were also higher in the varicose veins, and the elevation of bromine was seen in the normal group. conclusion: pixe analysis showed higher concentrations of trace elements in veins derived from varicos patients compared to normal group. the difference in normal and abnormal vein might be independent of age. iran. j. radiat. res., 2010 8 (2): 117-121
منابع مشابه
A proton induced X-ray emission (PIXE) analysis of concentration of trace elements in varicose veins
Background: Proton induced X-ray emission (PIXE) has been applied as reliable and improved techniques in this study to compare concentration of various trace elements in normal and abnormal varicose veins. Materials and Methods: Five samples from normal veins and 13 samples from varicose veins bombarded by 2.0 MeV energy proton beams produced by a Van de Graff accelerator in vacuum. T...
متن کاملA pixe analysis for measuring the trace elements concentration in breast tissue of Iranian women
Background: A powerful and improved technique, Proton Induced X-ray Emission (PIXE) has been performed-yielding the elemental composition of 17 samples of surgically excised malignant and normal tumors of breast tissue. The samples without any further process as thick targets were put on capton foil backing. There are no homogenizing processes. The PIXE spectra analysis was performed using he n...
متن کاملThe concentration of heavy trace elements in pigment and cholesterol humangallstones: Comparative studies by PIXE analysis.
Background: The method of proton induced X-ray emission (PIXE) has been widely used as a sensitive technique to trace elemental analysis in both biological and medical fields. The sensitivity of this powerful method is in the order of ppm .The aim of this work is to analyze structural composition of 4 heavy trace elements with Z greater than 24 (Mn, Fe, Cu, Zn) in two kinds of gallstones and to...
متن کاملProton-induced X-ray Emission
Black particles, collected by filtration (1.2~pm pore size) from the anoxic waters of a soft-water lake, were examined by a scanning proton microprobe which permitted quantitative elemental analysis by proton-induced X-ray emission (PIXE) and Rutherford backscattering (RBS). There was a uniform distribution of sulfur across the filter, but Fe, and to a lesser extent, Mn, was localized in -5-pm-...
متن کاملInvestigation of heavy trace elements in neoplastic and non-neoplastic human thyroid tissue: A study by proton-induced X-ray emissions.
Background: Within the context of developing techniques to facilitate the diagnosis of the thyroid diseases, the elemental composition of pathological thyroid tissue (neoplastic and non-neoplastic) was investigated by proton induced X-ray emission. The PIXE has been widely used as a sensitive technique for trace elemental analysis in both biological and medical fields. Materials and Methods: Th...
متن کاملa pixe analysis for measuring the trace elements concentration in breast tissue of iranian women
background: a powerful and improved technique, proton induced x-ray emission (pixe) has been performed-yielding the elemental composition of 17 samples of surgically excised malignant and normal tumors of breast tissue. the samples without any further process as thick targets were put on capton foil backing. there are no homogenizing processes. the pixe spectra analysis was performed using he n...