dose estimation with the calibration of dose-response curve of micronucleus in human peripheral lymphocytes induced by 50mev proton beams
نویسندگان
چکیده
background: the purpose of this paper is to establish an easy and reliable biodosimeter protocol to evaluate the biological effects of proton beams. materials and methods: human peripheral blood lymphocytes were irradiated using proton beams (let: 34.6 kev μm−1), and the chromosome aberrations induced were analyzed using cytokinesis-blocked (cb) micronucleus (mn) assay. to determine the efficiency of mn assay in estimating the doses received by 50mev proton beams and to monitor predicted dose of victims in accidental exposure, here we have evaluated the performance of mn analysis in a simulated situation after exposure with proton beams. peripheral lymphocytes were irradiated by 50mev proton beams up to 6gy and analyzed by giemsa staining of cb mn assay. results: the detected mn was found to be a significant dose-effect curve in the manner of dose-dependent increase after exposure with proton beams in vitro. when plotting on a linear scale against radiation dose, the line of best fit was y=0.004+(1.882x10-2±9.701x10-5) d+(1.43x10-3±1.571x10-5)d2. our results show a trend towards increase of the number of mn with increasing dose. it was linear-quadratic and has a significant relationship between the frequencies of mn and dose (r2= 0.9996). the number of mn in lymphocyte that was observed in control group is 5.202±0.04/cell. conclusion: hence, this simple protocol will be particularly useful for helping physicians to decide medical therapy for the initial treatment of victims with rapid and precise dose estimation after accidental radiation exposure. also it has potential for use as a valuable biomarker to evaluate the biological effectiveness for cancer therapy with proton beams. iran. j. radiat. res., 2011 8(4): 231-236
منابع مشابه
Dose estimation with the calibration of dose-response curve of micronucleus in human peripheral lymphocytes induced by 50MeV proton beams
Background: The purpose of this paper is to establish an easy and reliable biodosimeter protocol to evaluate the biological effects of proton beams. Materials and Methods: Human peripheral blood lymphocytes were irradiated using proton beams (LET: 34.6 keV μm−1), and the chromosome aberrations induced were analyzed using cytokinesis-blocked (CB) micronucleus (MN) assay. To determine th...
متن کاملDose estimation with the calibration of dose-response curve of micronucleus in human peripheral lymphocytes induced by 50MeV proton beams
*Corresponding authors: Prof. Tae-Hwan Kim Kim and Chang-Mo Kang, College of Veterinary Medicine, Kyungpook National University, Daegu city, 702-701, Republic of Korea. Fax: +82 53 950 5977 E-mail: [email protected], [email protected] Background: The purpose of this paper is to establish an easy and reliable biodosimeter protocol to evaluate the biological effects of proton beams. Materials and...
متن کاملRadio-adaptive response of peripheral blood lymphocytes following bystander effects induced by preirradiated CHO-K1 cells using the micronucleus assay
Background: Radio-adaptive response and bystander effects are known phenomena occurring in cells following exposure to ionizing radiation (IR). In this study we examined possible radio-adaptation of lymphocytes following bystander effects induced by CHO-K1 cells. Materials and Methods: Whole blood and CHO-K1 cells were cultured in RPMI-1640 complete medium. Cells were separately irradiated with...
متن کاملDose rate effect of pulsed electron beam on micronucleus frequency in human peripheral blood lymphocytes.
The micronucleus assay in human peripheral blood lymphocytes is a sensitive indicator of radiation damage and could serve as a biological dosimeter in evaluating suspected overexposure to ionising radiation. Micronucleus (MN) frequency as a measure of chromosomal damage has also extensively been employed to quantify the effects of radiation dose rate on biological systems. Here we studied the e...
متن کاملDetermination of dose-response relationship in cultured human lymphocytes for biological dosimetry
Background: Lymphocyte-dicentric assay is the most generally accepted method for biological dosimetry of overexposed individuals. In this study, the frequency of unstable chromosome aberration in blood lymphocytes was used to estimate radiation dose received by individuals. Evaluation of dose using a calibration curve produced elsewhere may have a significant uncertainty therefore, experiments ...
متن کاملEstablishment of a Dose-response Curve for X-ray-Induced Micronuclei in Human Lymphocytes
The cytokinesis-block micronucleus assay in peripheral blood lymphocytes is an established technique for biodosimetry. The aim of this project was to generate a X-ray induced micronuclei (MN) curve for peripheral blood lymphocytes taken from five healthy donors. The blood samples were irradiated with X-rays of 122 KeV at a dose rate of 0.652 Gy/min to doses of 0.5, 1, 2, 3, and 4 Gy. The blood ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of radiation researchجلد ۸، شماره ۴، صفحات ۲۳۱-۲۳۶
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023