fabrication of low cost in-house slab homogeneous and heterogeneous phantoms for lung radiation treatment

نویسندگان

s. senthilkumar department of radiotherapy, govt. rajaji hospital and madurai medical college, maduari-625 020, india

v. ramakrishnan deptartment of laser studies, madurai kamaraj university, madurai, tamil nadu, india

چکیده

background: the heterogeneous composition of the human body presents numerous tissue types and cavities with widely differing radiologic properties. the aim of the present work was to develop a low cost homogeneous and heterogeneous phantom and the absorbed dose were measured by ionization chamber for different radiotherapy treatment techniques and compared with treatment planning system absorbed dose values. materials and methods: present work deals with the fabrication of inexpensive homogeneous and heterogeneous tissue equivalent slab phantom using polymethyl methacrylate, cork, teflon and perspex as a tissue, lung, spine and tumor simulating materials respectively. these phantoms were used for different treatment techniques and full rotation techniques in ssd and sad techniques. results: the measured dose values for the different positions of both phantoms were compared with the tps values. the values are coinciding with each other and the percentage of deviation varies from 0.47 to 2.8 and 0.49 to 2.86 for heterogeneous and homogeneous phantoms respectively. conclusion: the measured values from ion chamber were compared with 3-d plato treatment planning system (tps). tps values were also revealed the same result for homogeneous and heterogeneous phantoms. the dose value of tumor is found to be gradually decreased with increase in arc angle. the dose value of spine is also found to be gradually decreased up to 90° and increased in 360°. heterogeneity correction would definitely improve the cancer treatment of the heterogeneity region. this in-house phantom is inexpensive, easy to handle and very useful one to verify the tps calculation. iran. j. radiat. res., 2011 9(2): 109-119

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of low cost in-house slab homogeneous and heterogeneous phantoms for lung radiation treatment

Background: The heterogeneous composition of the human body presents numerous tissue types and cavities with widely differing radiologic properties. The aim of the present work was to develop a low cost homogeneous and heterogeneous phantom and the absorbed dose were measured by ionization chamber for different radiotherapy treatment techniques and compared with treatment planning syst...

متن کامل

Design of homogeneous and heterogeneous human equivalent thorax phantom for tissue inhomogeneity dose correction using TLD and TPS measurements

Background: The purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the Treatment Planning Systems (TPS) calculated values for different lung treatment dosimetery. It is compared with Thermoluminescent Dosimeter (TLD) measurement. Materials and Methods: Homogeneous and heterogeneous tho...

متن کامل

Dose calculations accuracy of TiGRT treatment planning system for small IMRT beamlets in heterogeneous lung phantom

Background: Accurate dose calculations in small beamlets and lung material have been a great challenge for most of treatment planning systems (TPS).  In the current study, the dose calculation accuracy of TiGRT TPS was evaluated for small beamlets in water and lung phantom by comparison to Monte Carlo (MC) calculations. Materials and Methods: The head of Siemens Oncor-impression linac...

متن کامل

design of homogeneous and heterogeneous human equivalent thorax phantom for tissue inhomogeneity dose correction using tld and tps measurements

background: the purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the treatment planning systems (tps) calculated values for different lung treatment dosimetery. it is compared with thermoluminescent dosimeter (tld) measurement. materials and methods: homogeneous and heterogeneous tho...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۹، شماره ۲، صفحات ۱۰۹-۱۱۹

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023