tg-60 dosimetry parameters calculation for the β-emitter 153sm brachytherapy source using mcnp

نویسندگان

f. taghdiri department of nuclear engineering, science and research branch, islamic azad university, tehran, iran

m. sadeghi agricultural, medical and industrial research school, nuclear science and technology research institute, karaj, iran

s.h. hosseini department of nuclear engineering, science and research branch, islamic azad university, tehran, iran

m. athari department of nuclear engineering, science and research branch, islamic azad university, tehran, iran

چکیده

background: the formalism recommended by task group 60 (tg-60) of the american association of physicists in medicine (aapm) is applicable for β sources. radioactive biocompatible and biodegradable 153sm glass seed without encapsulation is a β- emitter with a short half life and delivers a high dose rate to the tumor in the millimeter range. in this work the dosimetry parameters of the seed for brachytherapy were evaluated. materials and methods: using mcnp4c code data, the dosimetric parameters of aapm tg-60 recommendations including the reference dose rate, the radial dose function and the anisotropy function were obtained. two dimensional dose distributions were also calculated. results: the dose rate at reference point was estimated to be 9.41 cgy.h-1.μci-1 for 153sm. 153sm with its relatively low energy beta component falls off the most rapidly of the other beta emitters. the calculated data was compared with that of several beta and photon emitting seeds. conclusion: the results showed the advantage of the beta emitting 153sm source in comparison with the other beta emitting sources, because of its rapid dose fall-off of beta-ray and high dose rate at the short distances of the seed. the results would be helpful in development of the radioactive implants using 153sm seeds for the brachytherapy treatment. iran. j. radiat. res.,2011 9(2): 103-108

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

TG-60 dosimetry parameters calculation for the β-emitter 153Sm brachytherapy source using MCNP

Background: The formalism recommended by Task Group 60 (TG-60) of the American Association of Physicists in Medicine (AAPM) is applicable for β sources. Radioactive biocompatible and biodegradable 153Sm glass seed without encapsulation is a β- emitter with a short half life and delivers a high dose rate to the tumor in the millimeter range. In this work the dosimetry parameters of the ...

متن کامل

Determining TG-43 brachytherapy dosimetry parameters and dose distribution for a 131Cs source model CS-1

Background: Monte Carlo determination of TG-43 brachytherapy dosimetry parameters and dose distribution calculation for 131Cs source model CS-1 are presented in this study. Materials and Methods: The dose distribution was calculated around the 131Cs Model CS-1 located in the center of 30 cm ×30 cm ×30 cm water, and soft tissue phantoms cube using MCNP code by Monte Carlo method. The percentage ...

متن کامل

Dose distribution and dosimetry parameters calculation of MED3633 palladium-103 source in water phantom using MCNP

Background: Palladium-103 (103Pd) is a brachytherapy source for cancer treatment. The Monte Carlo codes are usually applied for dose distribution and effect of shieldings. Monte Carlo calculation of dose distribution in water phantom due to a MED3633 103Pd source is presented in this work. Materials and Methods: The dose distribution around the 103Pd Model MED3633 located in the center of 30×...

متن کامل

Determining TG-43 brachytherapy dosimetry parameters and dose distribution for a 131Cs source model CS-1

Theoretical and experimental dosimetric studies have been supplied useful information on the dependence of the brachytherapy source geometry and materials (1-5). Usually, Monte Carlo method is used to define dose distribution function, the radial dose variation, and the dose calculation close to the source in brachytherapy. Chen et al. (6). calculated the distribution of absorbed dose around co...

متن کامل

determining tg-43 brachytherapy dosimetry parameters and dose distribution for a 131cs source model cs-1

background: monte carlo determination of tg-43 brachytherapy dosimetry parameters and dose distribution calculation for 131cs source model cs-1 are presented in this study. materials and methods: the dose distribution was calculated around the 131cs model cs-1 located in the center of 30 cm ×30 cm ×30 cm water, and soft tissue phantoms cube using mcnp code by monte carlo method. the percentage ...

متن کامل

dose distribution and dosimetry parameters calculation of med3633 palladium-103 source in water phantom using mcnp

background: palladium-103 (103pd) is a brachytherapy source for cancer treatment. the monte carlo codes are usually applied for dose distribution and effect of shieldings. monte carlo calculation of dose distribution in water phantom due to a med3633 103pd source is presented in this work. materials and methods: the dose distribution around the 103pd model med3633 located in the center of 30×30...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۹، شماره ۲، صفحات ۱۰۳-۱۰۸

کلمات کلیدی
[ ' b e t a e m i t t e r s ' , 1 5 3 , ' s m s e e d ' , ' d o s i m e t r y ' , ' t g ' , ' 6 0 p r o t o c o l ' , ' m c n p 4 c c o d e ' ]

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023