experimental and monte carlo studies on the response of cr-39 detectors to am-be neutron spectrum

نویسندگان

m.r. deevband department of biophysics, tarbiat modares university, tehran, iran

p. abdolmaleki department of biophysics, tarbiat modares university, tehran, iran

m.r. kardan nuclear sciences research school, radiation applications research school, tehran, iran

h.r. khosravi nuclear sciences research school, nuclear sciences and technology research institute, tehran, iran

چکیده

background: the poly-allyl diglycol carbonate (padc) detector is of particular interest for development of a fast neutron dosimeter. fast neutrons interact with the constituents of the cr-39 detector and produce h, c and o recoils, as well as (n, α) reaction. these neutron- induced charged particles contribute towards the response of cr-39 detectors. material and methods: electrochemical etching was used to enlarge track diameter which was made by low energy recoil protons. before electrochemical etching, a chemical etching was performed for 1 hour. the responses were also calculated by monte carlo simulations, using mcnpx code in different energy bins considering h, c and o recoils. the total registered efficiency and partial contributions of the efficiency, due to interactions with each constituent of cr-39, were calculated. results: the optimized condition of etchant was obtained to be 6n koh 15kv.cm-1, and 6 hours etching time. the obtained results show that track efficiency of cr-39 was a function of incident neutron energy. the tracks caused by o and c recoil nuclei were negligible for neutron energies lower than 1 mev. at neutron energies lower than 1 mev, only recoil protons would have sufficient energy to leave visible tracks. but, o and c recoils had important contributions in overall response of padc at neutron energies of few mev. conclusion: the efficiency of a cr-39 based dosemeter could be calculated by mcnpx code and the results were in a good agreement with experimental results in energy range of 241am – be bare source and 241am-be was softened with a spherical polyethylene moderator of radius of 20 cm. iran. j. radiat. res., 2011 9(2): 95-102

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum

Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produce H, C and O recoils, as well as (n, α) reaction. These neutron- induced charged particles contribute towards the response of CR-39 detectors. Material and Methods: Electrochemical...

متن کامل

Experimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum

*Corresponding author: Dr. Parviz Abdolmaleki, Department of Biophysics, Tarbiat Modares University, P. O. Box 14155-6446, Tehran, Iran. Fax: +98 21 82884717 E-mail: [email protected] Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produc...

متن کامل

Calculating CR-39 Response to Radon in Water Using Monte Carlo Simulation

Introduction CR-39 detectors are widely used for Radon and progeny measurement in the air. In this paper, using the Monte Carlo simulation, the possibility of using the CR-39 for direct measurement of Radon and progeny in water is investigated. Materials and Methods Assuming the random position and angle of alpha particle emitted by Radon and progeny, alpha energy and angular spectrum that arri...

متن کامل

Experimental and Monte Carlo simulation studies of open cylindrical radon monitoring device using CR-39 detector.

There are several methods of measuring radon concentrations but nuclear track detector cylindrical dosimeters are widely employed. In this investigation, the consequence of effective volumes of the dosimeters on the registration of alpha tracks in a CR-39 detector was studied. In a series of experiments an optimum radius for a CR-39-based open cylindrical radon dosimeter was found to be about 3...

متن کامل

calculating cr-39 response to radon in water using monte carlo simulation

introduction cr-39 detectors are widely used for radon and progeny measurement in the air. in this paper, using the monte carlo simulation, the possibility of using the cr-39 for direct measurement of radon and progeny in water is investigated. materials and methods assuming the random position and angle of alpha particle emitted by radon and progeny, alpha energy and angular spectrum that arri...

متن کامل

Designing an Am-Be miniature neutron source

Background: Miniature neutron sources with high neutron flux have abundant applications in medicine, industry and researches. The most important general characteristic of miniature neutron sources is their diameter which is 3mm in average. In this research, we have surveyed and designed an Am-Be miniature neutron source fabrication. Materials and Methods: This investigation resulted in creation...