patient doses from x-ray computed tomography examinations by a single-array detector unit: axial versus spiral mode

نویسندگان

s.m. ghavami radiology department, paramedical school, tabriz university of medical sciences, tabriz, iran

a. mesbahi medical physics department, medical school, tabriz university of medical sciences, tabriz, iran

i. pesianian radiology department, paramedical school, tabriz university of medical sciences, tabriz, iran

چکیده

background: x-ray computed tomography (ct) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. the objective of the current study was to analyze and investigate the average patient received dose from axial and spiral ct exams in a medical imaging center. material and methods: in this study, the patient imaging technique, weight and height were recorded. the patients’ doses provided by ct unit in terms of ctdiw were also recorded. then, other dosimetric quantities including dose-length product (dlp) and effective dose were calculated for each patient using the recorded data. the average values were obtained for all the studied dosimetric quantities. also, their distribution in terms of examined regions and imaging mode ie, axial and spiral ct were analyzed by spss software. results: for all patients, the mean effective dose of 4.4 mgy with the standard deviation of 9.2 was found. the ctdiw for axial group was two times higher than spiral ones. conversely, the effective dose of axial group was less than spiral group. additionally, the effective doses of 2.3 and 5.2 msv were found for axial and spiral, receptively. for both quantities of ctdiw and effective dose, the observed difference between axial and spiral modes were significant (p<0.001). conclusion: our results showed that although the patient doses in the current study was comparable with the reported values by similar studies in other countries, it was higher than the reported values of a similar study in iran. exposure technique’s optimaization and further review in routine ct examinations were recommended. iran. j. radiat. res., 2012 10(2): 89‐94

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode

Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...

متن کامل

Letter to editor

Dear Prof. Mozdarani,I would like to discuss about some important aspects regarding the article published in, "Iran. J. Radiat. Res., 2012 10(2): 89-94“ with title of “Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode" by Ghavami et al. (1), so according to journal policy and in suitable manner please ask the authors to rep...

متن کامل

Doses Received by Patients during Thorax X-Ray Examinations

Introduction Radiation exposures from diagnostic medical examinations are generally low and are almost always justified by the benefits of accurate diagnosis of possible disease conditions. Therefore, entrance skin dose (ESD), body organ dose (BOD), and effective dose (ED) from adult patients undergoing routine thorax posterior-anterior (PA) and thorax right lateral (RLAT) were estimated in Uni...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

doses received by patients during thorax x-ray examinations

introduction radiation exposures from diagnostic medical examinations are generally low and are almost always justified by the benefits of accurate diagnosis of possible disease conditions. therefore, entrance skin dose (esd), body organ dose (bod), and effective dose (ed) from adult patients undergoing routine thorax posterior-anterior (pa) and thorax right lateral (rlat) were estimated in uni...

متن کامل

Performance Evaluation of a Modular Detector Unit for X-Ray Computed Tomography

A research prototype CT scanner is currently under development in our lab. One of the key components in this project is the CT detector. This paper describes the design and performance evaluation of the modular CT detector unit for our proposed scanner. It consists of a Photodiode Array Assembly which captures irradiating X-ray photons and converts the energy into electrical current, and a mini...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۱۰، شماره ۲، صفحات ۸۹-۹۴

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023