dose enhancement effect of gold nanoparticles on magica polymer gel in mega voltage radiation therapy

نویسندگان

m. khadem-abolfazli physics department, mazandaran university, babolsar, iran

m. mahdavi physics department, mazandaran university, babolsar, iran

s.r.m. mahdavi medical physics department, iran university of medical sciences, tehran, iran

gh. ataei para medical school, babol university of medical sciences, babol, iran

چکیده

background: radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. material and methods: in this study, to evaluate dose characteristic of the normoxic polymer gel (magica) such as dose response , dose sensitivity and dose resolution and to find the gold nanoparticles (50 nm) effects of the normoxic polymer gel such as a def in mega voltage radiation therapy (18 mv-x ray). also it is compared by method of monte carlo simulation with mcnpx code. results: the results shown that the magica polymer gel dose response in dose range of 0 to 600 cgy is linear and dose resolution in this range, is less than 0.7 gy. magica polymer gel dosimeter response r2 was increased by added gold nanoparticles. absorbed dose enhancement factor by adding of gold nanoparticles with the 0.1, 0.2, 0.4 mm concentrations was 10%, 2% and 4% respectively. conclusion: in this study, shielding effect or self absorption happened on 0.2 mm & 0.4 mm. and optimum gold nanopartiles concentration to achieved maximum absorbed doe is 0.1mm, so that is useable for clinical studies.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose enhancement effect of gold nanoparticles on MAGICA polymer gel in mega voltage radiation therapy

Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. Among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. Material and Methods: In this study...

متن کامل

Gel dosimetry: The effect of gold nanoparticles on the dose enhancement in the external radiation therapy

Background: Normoxic type MAGICA gel dosimeters are established for dose quantification in three dimensions for radiotherapy. Objective(s): The ability of MAGICA polymer gel was assessed by experimental measurements method for studying the effect of gold nanoparticles (GNPs) in dose enhancement under the external 18MV radiotherapy practices. <...

متن کامل

Effect of Gold Nanoparticle on Percentage Depth Dose Enhancement On Megavoltage Energy in MAGICA Polymer Gel Dosimeter

Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date.Objective: The aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material.Methods: In this work t...

متن کامل

Evaluation of Gold Nanoparticle Size Effect on Dose Enhancement Factor in Megavoltage Beam Radiotherapy Using MAGICA Polymer Gel Dosimeter

Background: Gold nanoparticles (GNPs) are among the most promising radiosensitive materials in radiotherapy. Studying the effective sensitizing factors such as nanoparticle size, concentration, surface features, radiation energy and cell type can help to optimize the effect and possible clinical application of GNPs in radiation therapy. In this study, the radiation sensitive polymer gel was use...

متن کامل

Effect of gold nanoparticles on dose enhancement of 6 Mv X-rayin MAGIC_f polymer gel dosimeter

Introduction: Currently, the potential application of gold nanoparticles (AuNPs) to increase the efficiency of radiation therapy have been investigated. However, the loss of an appropriate method to estimate the dose distribution in nanoparticle laden tissue limits the applicability of nanoparticles in radiotherapy clinics. Polymer gel dosimetry provides an accurate and precise...

متن کامل

Effect of Gold Nanoparticle on Percentage Depth Dose Enhancement On Megavoltage Energy in MAGICA Polymer Gel Dosimeter

BACKGROUND Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date. OBJECTIVE The aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material. METHODS In this wor...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۱۱، شماره ۱، صفحات ۵۵-۶۱

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023