background: intraoperative radiation therapy (iort) technique is used to treat a surgically exposed tumor or tumor bed in the treatment of locally advanced intraabdominal, retroperitoneal, pelvic, thoracic, breast and soft tissue tumors. one way to perform iort is to use an existing linac and modify the treatment head using an applicator system. in this study the objectives were to design, and build an in-house iort applicator system, perform an acquisition of dosimetry data and characterize the iort radiation parameters. materials and methods: iort applicator system developed in this research consists of three flat applicators with inner diameters ( ф) of 3, 5 and 9 cm and one tube ( ф =3 cm) with a 45-degree beveled end. beam characteristics evaluated include percent depth dose distributions, beam profiles, and leakage dose distributions. measurements were performed using a scanditronix (p-si) diode field detector in a scanditronix (rfaplus) 3-d water phantom. results: compared to the standard applicator, depth dose curves for intra-operative cones are shallower surface dose is higher and the maximum peripheral dose is in the order of 9.6%. conclusion: using a 10 mev electron beam, the cone system developed in this study is suitable for treating tumors of width and depth ranges of 1.9-8.4 cm and 14-29 mm, respectively.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Beam characteristics and leakage assessment of an in-house intra-operative electron applicator system

Background: Intraoperative radiation therapy (IORT) technique is used to treat a surgically exposed tumor or tumor bed in the treatment of locally advanced intraabdominal, retroperitoneal, pelvic, thoracic, breast and soft tissue tumors. One way to perform IORT is to use an existing linac and modify the treatment head using an applicator system. In this study the objectives were to design, and ...

متن کامل

Design and dosimetry characteristics of a commercial applicator system for intra‐operative electron beam therapy utilizing ELEKTA Precise accelerator

The design concept and dosimetric characteristics of a new applicator system for intraoperative radiation therapy (IORT) are presented in this work. A new hard-docking commercial system includes polymethylmethacrylate (PMMA) applicators with different diameters and applicator end angles and a set of secondary lead collimators. A telescopic device allows changing of source-to-surface distance (S...

متن کامل

Physical characteristics of electron beam from conventional and beam shaper IOERT applicator: A comparison study

Introduction: Intraoperative electron radiation therapy (IOERT) is one of the cancer treatment techniques that delivers high doses to tumor bed during surgery. IOERT can be performed by either conventional LINACs or dedicated IORT accelerators such as LIAC (Light Intraoperative Accelerator). Two types of applicators can be used with LIAC dedicated accelerator including conventi...

متن کامل

Comparing experimental assessment of the peripheral dose outside the applicator in electron beams of ELEKTA with Treatment planning system

Introduction: The use of electrons in the electron therapy to destroy tumoral tissue is dedicated significant contribution of different methods of radiation therapy. Scattered radiation due to exited electrons of the applicator affect the dose out of the field in the patient's normal tissue. The aim of this study is to determine the peripheral dose outside the applicator in the...

متن کامل

development and implementation of an optimized control strategy for induction machine in an electric vehicle

in the area of automotive engineering there is a tendency to more electrification of power train. in this work control of an induction machine for the application of electric vehicle is investigated. through the changing operating point of the machine, adapting the rotor magnetization current seems to be useful to increase the machines efficiency. in the literature there are many approaches wh...