staff dose assessment from coronary angiography

نویسندگان

gh. fallah mohammadi department of radiology, paramedical faculty, mazandaran university of medical sciences, sari, iran

m. vahabi moghadam department of physics, faculty of science, university of guilan, rasht, iran

m. ghanbar moghadam department of physics, faculty of science, university of guilan, rasht, iran

چکیده

background: interventional cardiology procedures such as coronary angiography (ca) and percutaneous transluminal coronary angiography (ptca) has been increased recent years. the purpose of this study was to measurement of effective dose to cardiology staffs who operate near the patient and are exposed to non-uniform radiation field due to patient scattered radiation. materials and methods: this study was performed in angiography department of fatemeh zahra hospital as specialized hospital of heart in sari, the northern city of iran for two months and 687 interventional cardiology procedures were studied. doses were recorded with thermoluminescence dosimeter (tld) for 10 cardiologists, 10 nurses and 1 radiology technologist and the effective dose were estimate using the niklason algorithm. results: mean annual effective dose (µsv ) to cardiologist and nurses and radiology technologist from interventional cardiology procedures were 535.57 (68.6 – 1984.8) µsv and 153.7 (59.5 – 277.2) µsv respectively. mean effective dose (µsv) per interventional cardiology procedure for cardiologist and nurses and radiology technologist were 2.123 and 0.274 µsv respectively. conclusion: the results indicate large variation in radiation exposure between staffs. no correlation was found between the number of procedures and effective dose. none of the annual effective dose appear to exceed the annual effective dose limit of 20 msv.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Staff dose assessment from coronary angiography

Background: Interventional cardiology procedures such as coronary angiography (CA) and percutaneous transluminal coronary angiography (PTCA) has been increased recent years. The purpose of this study was to measurement of effective dose to cardiology staffs who operate near the patient and are exposed to non-uniform radiation field due to patient scattered radiation. Materials and Methods: This...

متن کامل

Assessment of patients skin dose undergoing coronary angiography and Percutaneous Transluminal Coronary Angioplasty (PTCA)

Background: Practice of interventional cardiology procedures such as Coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) has largely increased in recent years and is now changing to a matter of routine in many hospitals. The purpose of this study was to measure skin and organ doses in patients undergoing CA and PTCA and to find a probable relation with c...

متن کامل

Patient and Staff Doses from Digital Bi-plane Coronary Angiography

INTRODUCTION Coronary Angiography is the standard technique for imaging the left ventricle and coronary arteries. Within the spectrum of diagnostic imaging coronary Angiography is a high dose procedure. The number of examination has significantly increased in recent years, partly due to the introduction of diagnostic X-ray equipment with improved imaging capabilities. This has resulted not only...

متن کامل

assessment of patients skin dose undergoing coronary angiography and percutaneous transluminal coronary angioplasty (ptca)

background: practice of interventional cardiology procedures such as coronary angiography (ca) and percutaneous transluminal coronary angioplasty (ptca) has largely increased in recent years and is now changing to a matter of routine in many hospitals. the purpose of this study was to measure skin and organ doses in patients undergoing ca and ptca and to find a probable relation with cardiologi...

متن کامل

Asymmetric breast dose in coronary angiography

The purpose of this study was to demonstrate asymmetric radiation dose distribution to the breasts in coronary angiography. Gafchromic XR-QA2 film was used as an area dosimeter to capture the asymmetric dose distribution to the breasts at various tissue depths in an anthropomorphic phantom. A selection of tube angulations were used under a controlled experiment and during a mock coronary angiog...

متن کامل

Coronary Vasospastic Angina: Assessment by Multidetector CT Coronary Angiography

OBJECTIVE We aimed to describe the imaging findings of multidetector CT coronary angiography (MDCTA) in cases of vasospastic angina (VA) and to determine the accuracy of MDCTA in the identification of VA as compared with invasive coronary angiography with an ergonovine provocation test (CAG with an EG test). MATERIALS AND METHODS Fifty-three patients with clinically suspected VA were enrolled...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۱۲، شماره ۱، صفحات ۷۵-۷۸

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023