the basic radiation properties of the n-isopropylacrylamide based polymer gel dosimeter

نویسندگان

a.r. farajollahi department of medical physics, faculty of medicine, tabriz university of medical sciences, tabriz, iran

f. pak department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran

m. horsfield department of cardiovascular sciences, university of leicester, leicester royal infirmary, leicester, uk

z. myabi department of radiology, emam reza teaching hospital, tabriz university of medical sciences, tabriz, iran

چکیده

background: in this study the basic radiation properties of n-isopropylacrylamaide polymer gel dosimeter were determined together with verification of its soft tissue equivalency. materials and methods: the nipam gel was prepared and irradiated approximately 2 h after manufacturing. the magnetic resonance (mr) images were made 24 h after irradiation. the nuclear magnetic resonance (nmr) response (r2) of the dosimeters was analyzed for conditions of varying dose, batch, dose rate, time post-irradiation and energy. in order to verify tissue equivalence of nipam dosimeter, several parameters such as physical density, effective atomic number, relative electron density, ct (computed tomography) number and also elemental composition were determined and compared with those for soft tissue. results: the response of the gel was found to be stable 24 hours after irradiation. the results showed that the dose response of the nipam polymer gel is reproducible in same and different batches of chemical and the gel response was linear up to 26 gy with r2=0.995. in the measured range, the dose response of the nipam gel is independent of beam energy within less than ±0.02 and the dose rate had no effect on the gel response. this polymer gel has been found to be tissue equivalent. conclusion: nipam gel dosimeter appears to be a promising dosimeter in all aspects of dosimetric properties which were assessed in this study, in addition to the advantage of reduced toxicity which it has over other polymer gels.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The basic radiation properties of the N-isopropylacrylamide based polymer gel dosimeter

Background: In this study the basic radiation properties of N-isopropylacrylamaide polymer gel dosimeter were determined together with verification of its soft tissue equivalency. Materials and Methods: The NIPAM gel was prepared and irradiated approximately 2 h after manufacturing. The magnetic resonance (MR) images were made 24 h after irradiation. The nuclear magnetic resonance (NMR) respons...

متن کامل

Basic investigation on performance of low-density polymer gel dosimeter

Background:  In this study a series of basic dosimetric properties of a low-density (LD) gel dosimeter are investigated. The dose response is studied regarding to linearity, sensitivity, dose-rate and energy dependence as well as lung tissue equivalence. Materials and Methods: The LD gel was made by mixing the polymer gel with expanded polystyrene spheres. Energy dependence was studied...

متن کامل

Effect of Composition Interactions on the Dose Response of an N-Isopropylacrylamide Gel Dosimeter

In this study, a two-level full factorial design was used to identify the effects of the interactions between compositions in an N-isopropylacrylamide (NIPAM) gel dosimeter involving the following variables: (A) gelatin, (B) NIPAM, (C) the crosslinker N, N'-methylene-bis-acrylamide (Bis), and (D) the antioxidant tetrakis (hydroxymethyl) phosphonium chloride (THPC). The dose range was from 0 Gy ...

متن کامل

basic investigation on performance of low-density polymer gel dosimeter

background:  in this study a series of basic dosimetric properties of a low-density (ld) gel dosimeter are investigated. the dose response is studied regarding to linearity, sensitivity, dose-rate and energy dependence as well as lung tissue equivalence. materials and methods: the ld gel was made by mixing the polymer gel with expanded polystyrene spheres. energy dependence was studied at two d...

متن کامل

Optical and NMR dose response of N-isopropylacrylamide normoxic polymer gel for radiation therapy dosimetry.

BACKGROUND Application of less toxic normoxic polymer gel of N-isopropyl acrylamide (NIPAM) for radiation therapy has been studied in recent years. AIM In the current study the optical and NMR properties of NIPAM were studied for radiation therapy dosimetry application. MATERIALS AND METHODS NIPAM normoxic polymer gel was prepared and irradiated by 9 MV photon beam of a medical linac. The o...

متن کامل

control of the optical properties of nanoparticles by laser fields

در این پایان نامه، درهمتنیدگی بین یک سیستم نقطه کوانتومی دوگانه(مولکول نقطه کوانتومی) و میدان مورد مطالعه قرار گرفته است. از آنتروپی ون نیومن به عنوان ابزاری برای بررسی درهمتنیدگی بین اتم و میدان استفاده شده و تاثیر پارامترهای مختلف، نظیر تونل زنی(که توسط تغییر ولتاژ ایجاد می شود)، شدت میدان و نسبت دو گسیل خودبخودی بر رفتار درجه درهمتنیدگی سیستم بررسی شده اشت.با تغییر هر یک از این پارامترها، در...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۱۲، شماره ۴، صفحات ۳۴۷-۳۵۴

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023