hvl evaluation of orthovoltage x-ray machine using egsnrc code of simulation
نویسندگان
چکیده
background: making use of the orthovoltage machines in radiotherapy, is one of the routine methods for the treatment of the superficial lesions. in this study, an important determinant of x-ray quality, the hvl (half value layer), has been evaluated. materials and methods: the hvls of a orthovoltage x-ray machine in 120 and 180 kvp are measured, using an empirical method, in which the hvls are derived from the absorption curves. the measured hvls are compared with calculated (monte carlo simulation) hvls. using the beamdp code of simulation, the output spectra are obtained and employed for the measurement of the hvls. results: comparing the calculated and measured hvl values, the results show that the highest and lowest differences between the two are 4.96% and 2.27%, respectively, which are, in fairly good agreement with those obtained in the former studies. conclusion: this study shows that the egsnrc simulation code is capable of being used for the extraction of the quality indices for the superficial x-ray radiotherapy machines. it seems that, the mentioned code, with the mentioned experimental method, can be employed as a routine clinical test tool for every superficial radiotherapy department.
منابع مشابه
HVL evaluation of orthovoltage X-ray machine using EGSnrc code of simulation
Background: Making use of the orthovoltage machines in Radiotherapy, is one of the routine methods for the treatment of the superficial lesions. In this study, an important determinant of X-ray quality, the HVL (Half Value Layer), has been evaluated. Materials and Methods: The HVLs of a orthovoltage X-ray machine in 120 and 180 kVp are measured, using an empirical method, in which the HVLs are ...
متن کاملAccuracy Evaluation of Oncentraâ„¢ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code
Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computat...
متن کاملX-ray spectra calculation for different target-filter of mammograms using MCNP Code
ABSTRACTBackground: An electron beam generated X-ray spectrum consists of characteristic X-ray and continuous bermsstrahlung. The aim of this research is calculating and comparing X-ray spectra for different target filter of mammograms. Materials and Methods: Monte Carlo is a very powerful tool to simulate a series of different target-filter assembly in order to calculate the X-ray spectra. MC...
متن کاملhazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures
شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...
Siemens primus accelerator simulation using EGSnrc Monte Carlo code and gel dosimetry validation with optical computed tomography system by EGSnrc code
Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of radiation researchجلد ۱۲، شماره ۴، صفحات ۳۲۵-۳۳۰
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023