clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography

نویسندگان

d. han medical imaging center, the first hospital affiliated kunming medical college, kunming, 650032, china

x.j. xie medical imaging center, the first hospital affiliated kunming medical college, kunming, 650032, china

l. wen medical imaging center, the first hospital affiliated kunming medical college, kunming, 650032, china

چکیده

background: this study set out to evaluate the utility of cerebrovascular virtual non-contrast (vnc) scans. materials and methods: conventional non-contrast (cnc) and dual-energy computed tomography angiography (de-cta) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified lesions. vnc images were extracted from the de-cta head scans by post-processing. the true (or conventional) and vnc images were compared in terms of the mean ct attenuation value and signal-to-noise ratio (snr) of the cerebral parenchyma, the image quality, the lesion detection sensitivity, and the radiation exposure level. results: the image qualities of the cnc and vnc scans were (4.95 ± 0.22) points and (3.94 ± 0.24) points (t = 31.18, p < 0.05), the mean ct values for the cnc and vnc images were (34.6 ± 2.44) and (28.6 ± 5.40) hu (t = 10.126, p < 0.05), the snrs were (9.45 ± 1.26) and (6.87 ± 1.77), and the hu for white matter was (t = 11.859, p<0.05), respectively. the effective radiation doses from the de-cta head scans and the conventional non-contrast scans were (8.55 ± 0.57) msv and (9.41 ± 1.00) msv, respectively. no significant difference in the lesion detection sensitivities was observed between the cnc and vnc scans, except for tiny calcified lesions, which could not be identified by a vnc scan. conclusion: vnc and contrast-enhanced images could be obtained from de-cta head scans and could aid in the diagnosis of cerebral lesions. the radiation dose from the vnc scan was less than that from the cnc scan.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography

Background: This study set out to evaluate the utility of cerebrovascular virtual non-contrast (VNC) scans. Materials and Methods: Conventional non-contrast (CNC) and dual-energy computed tomography angiography (DE-CTA) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified les...

متن کامل

Novel clinical applications of dual energy computed tomography.

Dual energy CT (DECT) was conceived at the very beginning of the computed tomography era. However the first DECT scanner was developed in 2006. Nowadays there are three different types of DECT available: dual-source CT with 80(100) kVp and 140 kVp tubes (Siemens Medical Solution); dual-layer multi-detector scanner with acquisition 120 or 140kVp (Philips Healthcare); CT unit with one rapid kVp s...

متن کامل

Dual source computed tomography coronary angiography in new onset cardiomyopathy.

AIM To evaluate safety and utility of coronary computed tomography angiography (CCTA) compared to invasive coronary angiography (ICA) in new cardiomyopathy. METHODS Eighteen patients (mean age 56.5 years, 10 males) who presented for evaluation of new onset heart failure with evidence of systolic dysfunction (ejection fraction < 40%) on echocardiography and recent ICA were prospectively enroll...

متن کامل

Optimal Contrast of Cerebral Dual-Energy Computed Tomography Angiography in Patients With Spontaneous Subarachnoid Hemorrhage

OBJECTIVE The aim of this study was to investigate the image quality of cerebral dual-energy computed tomography (CT) angiography using a nonlinear image blending technique as compared with the conventional linear blending method in patients with spontaneous subarachnoid hemorrhage (SAH). METHODS A retrospective review of 30 consecutive spontaneous SAH patients who underwent a dual-source, du...

متن کامل

Comparison of dual-source computed tomography (CT) dual-energy angiography with conventional 3D imaging towards caudomedial vessels

We aim to analyse the time consumption, image quality and efficacies of dual-source Computed Tomography (CT) Dual-Energy Angiography (DE-CTA) in diagnosing vascular stenosis. The medical records of 35 patients with clinically suspected caudomedial vascular diseases were performed DE-CTA. The residual bone images obtained in DE-CTA and conventional 3D software were compared, as well as the sensi...

متن کامل

Dual-energy computed tomography angiography: virtual calcified plaque subtraction in a vascular phantom

BACKGROUND Material decomposition of dual-energy computed tomography (DECT) enables subtraction of calcified plaque. PURPOSE To evaluate the accuracy of lumen area measurement in calcified plaque by subtraction of DECT and to determine the effect of contrast material concentration, lumen diameter, density, and thickness of calcified plaque for the measurement. MATERIAL AND METHODS Vessel ph...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۱۴، شماره ۲، صفحات ۱۵۹-۱۶۳

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023