pediatric dose assessment in common ct examination towards establishment of related regional drl in mazandaran, iran

نویسندگان

a. janbabanezhad-toori radiobiology and radiation protection, babol university of medical sciences, babol, iran

m.r. deevband department of medical physics and biomedical engineering, school of medicine, shahid beheshti university of medical sciences, tehran, iran

a. shabestani-monfared department of medical physics, faculty of medicine, babol university of medical sciences, babol, iran

r. abdi department of radiology, mazandaran university of medical sciences, sari, iran

چکیده

background: computed tomography (ct) is main contributor of population dose from diagnostic x-ray examinations. children are more radiosensitive than adults, thus optimization of ct examination in these patients is essential. the purpose of this study was to evaluate dose delivered to pediatric patients’ undergoing ct examination of the common examinations and also establishing local diagnostic reference levels (drls). materials and methods: questionnaires were designed for data collection at seven public hospitals and information about patient, protocol and ct system were recorded during 2013 and 2014. dose measurement was performed in four age groups: 0-1, 1-5, 5-10 and 10-15 years old and two ct dose quantity including ctdiw   and dlp were calculated. results: values  of 40, 48, 59.5, 59.5 mgy; 16.9, 16.9, 17.14, 17.14 mgy; 17, 17, 17, 17 mgy; 17, 17, 19.2, 19.2 mgy in terms of ctdiw and 448, 538, 758, 758 mgy cm; 129, 129, 154, 167 mgy cm; 184, 225, 306, 315 mgy cm; 289, 408, 595, 670 mgy cm in terms of dlp as regional drl for brain, sinus, chest, abdomen and pelvic examinations were obtained respectively. conclusion: the variations in dose of some examination were considerable. as the role and usage of ct technology continues to expand, it is important that all practitioners adapt optimized protocols, especially for pediatrics scanning, following proposed reference levels

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pediatric dose assessment in common CT examination towards establishment of related regional DRL in Mazandaran, Iran

Background: Computed Tomography (CT) is main contributor of population dose from diagnostic X-ray examinations. Children are more radiosensitive than adults, thus optimization of CT examination in these patients is essential. The purpose of this study was to evaluate dose delivered to pediatric patients’ undergoing CT examination of the common examinations and also establishing local Diag...

متن کامل

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

BACKGROUND Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. OBJECTIVE This study is aimed at evaluating radiation dose to patients from ...

متن کامل

dose assessment in computed tomography examination and establishment of local diagnostic reference levels in mazandaran, iran

background : medical x-rays are the largest man-made source of public exposure to ionizing radiation. while the benefits of computed tomography (ct) are well known in accurate diagnosis, those benefits are not risk-free. ct is a device with higher patient dose in comparison with other conventional radiation procedures. objective: this study is aimed at evaluating radiation dose to patients from...

متن کامل

Assessment of Patient Dose from CT Examinations in Khorasan, Iran

Introduction Computed Tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. Ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. Yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. Materials and Methods Two refe...

متن کامل

analyzing patterns of classroom interaction in efl classrooms in iran

با به کار گیری روش گفتما ن شنا سی در تحقیق حا ضر گفتا ر میا ن آموزگا را ن و زبا ن آموزا ن در کلا سهای زبا ن انگلیسی در ایرا ن مورد بررسی قرار گرفت. ا هداف تحقیق عبا رت بودند از: الف) شنا سا ئی سا ختارهای ارتبا ط گفتا ری میا ن معلمین و زبا ن آموزا ن ب) بررسی تا ثیر نقش جنسیت دبیرا ن و زبا ن آموزان بر سا ختا رهای ارتبا ط گفتا ری میا ن آنها پ) مشخص کردن اینکه آ یا آموزگاران غا لب بر این ارتبا ط گف...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۱۴، شماره ۳، صفحات ۲۵۱-۲۵۶

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023