assessment of indoor airborne pollutants of beam rolling mills factory
نویسندگان
چکیده
air pollutants from iron and steel making operations have historically been an environmental concern. the factory located at ahwaz, iran, has two production lines namely, 630 and 650, which produce iron parallel edge. the objective of the study is to determine indoor respiratory particulate matter (rpm) and feo concentrations and their comparison with niosh standards. this is a cross–sectional study of personnel working in different environmental conditions. there were significant differences in mean concentrations of rpm (p< 0.05) in line 650 but not in line 630 as compared to noish standard (3 mg/m3). the feo concentrations in line 630 and 650 are significantly lower than the niosh standard (5 mg/m3). there is maximum feo concentration in station 7 (0.8 mg/m3), due to remains of iron on the billets. in other words, after cutting the beam by saws, carried out with water pressure of 150 bar and immersing in cooling beds, the temperature decreases from 550 â°c to 150 â°c. as the result, airborne iron oxide concentrations decrease in the respiratory air zone of workers. there is maximum rpm concentration in station of billet rejecter for line 630 (7.645 mg/m3), because this station carries out peel action on metal. the primary form of rpm is not directly related to the iron handling but may be related to improper ventilation and exhaust system.
منابع مشابه
Investigation of respirable particulate matter pollutants on air-breathing zone workers in the Beam Rolling Mills Factory (Iran National Steel Industrial Group), Ahvaz, Iran
Workers of iron and steel factories are exposed to a wide range of pollutants depending on the particular process, the materials involved, the effectiveness of monitoring and the control measures. Adverse effects are determined by the physical state and propensities of the pollutant involved, the intensity and duration of the exposure, the extent of pollutant accumulation in the body and the se...
متن کاملAssessment of exposure to indoor air pollutants.
The World Health Organization is a specialized agency of the United Nations with primary responsibility for international health matters and public health. Through this Organization, which was created in 1948, the health professions of over 190 countries exchange their knowledge and experience with the aim of making possible the attainment by all citizens of the world of a level of health that ...
متن کاملassessment of the efficiency of s.p.g.c refineries using network dea
data envelopment analysis (dea) is a powerful tool for measuring relative efficiency of organizational units referred to as decision making units (dmus). in most cases dmus have network structures with internal linking activities. traditional dea models, however, consider dmus as black boxes with no regard to their linking activities and therefore do not provide decision makers with the reasons...
Assessment of air pollution and its effects on the health status of the workers in beam rolling mills factory (Iran National Steel Industrial Group) from Ahvaz-Iran
BACKGROUND Air pollutants of iron- and steel-making operations have historically been an environmental and health hazard. These pollutants include gaseous substances such as sulfur oxide, nitrogen dioxide, and carbon monoxide. The Iran National Steel Industrial Group beam rolling mills factory has two production lines viz. line 630 and line 650, with different beam production capabilities and i...
متن کاملthe impact of training on second language writing assessment: a case of raters’ biasedness
چکیده هدف اول این تحقیق بررسی تأثیر آموزش مصحح بر آموزش گیرندگان براساس پایایی نمره های آنها در پنج بخش شامل محتوا ، سازمان ، لغت ، زبان و مکانیک بود. هدف دوم این بود که بدانیم آیا تفاوتهای بین آموزشی گیرندگان زن و مرد در پایایی نمرات آنها وجود دارد. برای بررسی این موارد ، ما 90 دانشجو در سطح میانه (متوسط) که از طریق تست تعیین سطح شده بودند انتخاب شدند. بعد از آنها خواستیم که درباره دو موضوع ا...
15 صفحه اولassessment of the park- ang damage index for performance levels of rc moment resisting frames
چکیده هدف اصلی از طراحی لرزه ای تامین ایمنی جانی در هنگام وقوع زلزله و تعمیر پذیر بودن سازه خسارت دیده، پس از وقوع زلزله است. تجربه زلزله های اخیر نشان داده است که ساختمان های طراحی شده با آیین نامه های مبتنی بر نیرو از نظر محدود نمودن خسارت وارده بر سازه دقت لازم را ندارند. این امر سبب پیدایش نسل جدید آیین نامه های مبتنی بر عملکرد شده است. در این آیین نامه ها بر اساس تغییرشکل های غیرارتجاعی ...
15 صفحه اولمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
international journal of environmental researchجلد ۱، شماره ۳، صفحات ۲۳۷-۲۴۱
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023