an iterative process for pushover analysis of double unsymmetric-plan low- and medium-rise buildings under bi-directional excitation

نویسندگان

m. poursha department of civil engineering, sahand university of technology, new sahand town, tabriz, iran

چکیده

double- unsymmetric-plan medium-rise buildings subjected to bi-directional seismic excitation are complex structures where higher-mode effects in plan and elevation are important in estimating the seismic responses using nonlinear static or pushover analysis. considering two horizontal components of the ground motions makes the problem more intricate. this paper presents a method for nonlinear static analysis of double unsymmetric-plan low- and medium-rise buildings subjected to the two horizontal components of ground motions. to consider bi-directional seismic excitation in pushover analyses, the proposed method utilizes an iterative process until displacements at a control node (centre of mass at the roof level) progressively reach the predefined target displacements in both horizontal directions. in the case of medium-rise buildings, continuous implementation of modal pushover analyses is used to take higher-mode effects into account. to illustrate the applicability and to appraise the accuracy of the proposed method, it is applied to the 4- and 10-storey torsionally-stiff and torsionally-flexible buildings as representative of low- and medium-rise buildings, respectively. for the purpose of comparison, modal pushover analysis (mpa) is also implemented considering the two horizontal components of the ground motions. the results indicate that the proposed method and the mpa procedure can compute the seismic demands of double unsymmetric-plan low- and medium-rise buildings with reasonable accuracy however, seismic responses resulting from the proposed method deteriorate at the flexible edge of the torsionally-flexible buildings

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modal Pushover Analysis of SAC Buildings

The nonlinear static procedure (NSP) or pushover analysis in FEMA-273 [FEMA, 1997] has become a standard procedure in current structural engineering practice. Seismic demands are computed by nonlinear static analysis of the structure, which is subjected to monotonically increasing lateral forces with an invariant height-wise distribution until a target displacement is reached. None of the curre...

متن کامل

assessment of conventional nonlinear static procedures with fema load distributions and modal pushover analysis for high-rise buildings

the nonlinear static pushover analysis technique is mostly used in the performance-based design of structures and it is favored over nonlinear response history analysis. however, the pushover analysis with fema load distributions losses its accuracy in estimating seismic responses of long period structures when higher mode effects are important. some procedures have been offered to consider thi...

متن کامل

Modal Pushover Seismic Analysis of Sac Buildings excluding Gravity Loads

Evaluated is the accuracy of the modal pushover analysis in estimating the seismic demands for six SAC buildings, excluding gravity-loads and P-delta effects. These results are compared with those obtained by nonlinear response history analysis and three force distributions in FEMA-273.

متن کامل

development and implementation of an optimized control strategy for induction machine in an electric vehicle

in the area of automotive engineering there is a tendency to more electrification of power train. in this work control of an induction machine for the application of electric vehicle is investigated. through the changing operating point of the machine, adapting the rotor magnetization current seems to be useful to increase the machines efficiency. in the literature there are many approaches wh...

15 صفحه اول

Proposal of lateral load pattern for pushover analysis of RC buildings

The proposal lateral load pattern for pushover analysis is given in two forms for symmetric concrete buildings: 1-(X/H)0.5 for low-rise and mid-rise buildings, 2- Sin(ΠX/H) for high-rise buildings. These two forms give more realistic results as compared to conventional load patterns such as triangular and uniform load patterns. The assumed buildings of 4, 8, 12, 16, 20 and 30 story concrete bui...

متن کامل

An Energy Based Adaptive Pushover Analysis for Nonlinear Static Procedures

Nonlinear static procedure (NSP) is a common technique to predict seismic demands on various building structures by subjecting a monotonically increasing horizontal loading (pushover) to the structure. Therefore, the pushover analysis is an important part of each NSP. Accordingly, the current paper aims at investigating the efficiencyof various algorithms of lateral load patterns applied to the...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
international journal of civil engineering

جلد ۱۱، شماره ۲، صفحات ۱۰۰-۱۱۴

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023