performance of exterior precast concrete beam-column dowel connections under cyclic loading

نویسندگان

r. vidjeapriya department of civil engineering, college of engineering guindy, anna university, chennai, sardar patel road, guindy, chennai, india

v. vasanthalakshmi department of civil engineering, college of engineering guindy, anna university, chennai, sardar patel road, guindy, chennai, india

k. p. jaya department of civil engineering, college of engineering guindy, anna university, chennai, sardar patel road, guindy, chennai, india

چکیده

the present study focuses on the performance of precast concrete beam-column dowel connections subjected to cyclic loading by conducting experiments. in this study, one-third scale model of two types of precast and a monolithic beam-column connection were cast and tested under reverse cyclic loading. the precast connections considered for this study is a beam-column connection where beam is connected to column with corbel using (i) dowel bar and (ii) dowel bar with cleat angle. the experimental results of the precast specimens have been compared with that of the reference monolithic connection. the sub-assemblage specimens have been subjected to reverse cyclic displacement-controlled lateral loading applied at the end of the beam. the performance of the precast connections in terms of the ultimate load carrying capacity, post- elastic strength enhancement factor, load-displacement hysteresis behaviour, moment-rotation hysteresis behaviour, energy dissipation capacity, equivalent viscous damping ratio and ductility factor were compared with that of the monolithic beam-column connection. the monolithic specimen was found to perform better when compared to the precast specimens in terms of strength and energy dissipation. in terms of ductility, the precast specimen using dowel bar and cleat angle showed better behaviour when compared to the reference monolithic specimen.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite element analysis of precast hybrid-steel concrete connections under cyclic loading

In this paper, a nonlinear finite element (FE) analysis of hybrid-steel concrete connections is presented. The detailed experimental results of the four full-scale hybrid-steel concrete connections with limited seismic detailing have been discussed in a different paper. However, due to the inherent complexity of beam–column joints and the unique features of the tested specimens, the experimenta...

متن کامل

Performance of Dowel Bar Retrofitted Concrete Pavement Under HVS Loading

The California Department of Transportation uses Dowel Bar Retrofit (DBR) as a rehabilitation strategy for concrete pavements. Two test sections were dowel bar retrofitted and a third section was designated for control on US 101 near Ukiah, California. All three sections were subjected to accelerated pavement testing using the Heavy Vehicle Simulator (HVS). The HVS results demonstrated a large ...

متن کامل

Shear Performance of Horizontal Joints in Short Precast Concrete Columns with Sleeve Grouted Connections under Cyclic Loading

In this study, two short precast concrete columns and two cast-in-situ concrete columns were tested under cyclic loads. It was shown that the sleeve grouted connection was equivalent to the cast-in-situ connections for short columns when the axial compression ratio was 0.6. In order to determine the influence of the axial compression ratio and the shear-span ratio on the shear capacity of the h...

متن کامل

Performance of the Modified Precast Beam to Column Connection Placed on a Concrete Corbel

Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...

متن کامل

Analytical and Experimental Investigation of I Beam-to-CFT Column Connections under Monotonic Loading (RESEARCH NOTE)

In this study, the behavior characteristics of I beam-to-concrete filled tube (CFT) column connection is studied through experiment and finite element models under the monotonic loading. To validate the finite element modeling, at first, an experimental model is made and experimented. After validation of the finite element modeling, different models were created in the software. The studied par...

متن کامل

Mathematical Modeling of Column-Base Connections under Monotonic Loading

Some considerable damage to steel structures during the Hyogo-ken Nanbu Earthquake occurred. Among them, many exposed-type column bases failed in several consistent patterns, such as brittle base plate fracture, excessive bolt elongation, unexpected early bolt failure, and inferior construction work, etc. The lessons from these phenomena led to the need for improved understanding of column base...