dimensional stability of two polyvinyl siloxane impression materials in different time intervals
نویسندگان
چکیده
abstract statement of the problem: dental prosthesis is usually made indirectly; therefore dimensional stability of the impression material is very important. every few years, new impression materials with different manufacturers’ claims regarding their better properties are introduced to the dental markets which require more research to evaluate their true dimensional changes. objectives: the aim of this study was to evaluate dimensional stability of additional silicone impression material (panasil® and affinis®) in different time intervals. materials and methods: in this experimental study, using two additional silicones (panasil® and affinis®), we made sixty impressions of standard die in similar conditions of 23 °c and 59% relative humidity by a special tray. the die included three horizontal and two vertical lines that were parallel. the vertical line crossed the horizontal ones at a point that served as reference for measurement. all impressions were poured with high strength dental stone. the dimensions were measured by stereo-microscope by two examiners in three interval storage times (1, 24 and 168 hours). the data were statistically analyzed using t-test and anova. results: all of the stone casts were larger than the standard die. dimensional changes of panasil and affinis were 0.07%, 0.24%, 0.27% and 0.02%, 0.07%, 0.16% after 1, 24 and 168 hours, respectively. dimensional change for two impression materials wasn’t significant in the interval time, expect for panasil after one week ( p = 0.004). conclusions: according to the limitations of this study, affinis impressions were dimensionally more stable than panasil ones, but it was not significant. dimensional change of panasil impression showed a statistically significant difference after one week. dimensional changes of both impression materials were based on ada standard limitation in all time intervals (< 0.5%); therefore, dimensional stability of this impression was accepted at least until one week.
منابع مشابه
Dimensional Accuracy of Polyvinyl Siloxane Impression Materials Considering Impression Techniques– A Literature Review
Objectives Impression accuracy is the main determinant of the fit, form and function of prosthetic restorations. Polyvinyl siloxane (PVS) is the material of choice in most clinical situations. The purpose of this paper is to provide an up-to-date review of scientific articles which discuss the dimensional accuracy of PVS impression material using various impression techniques, tray types and sp...
متن کاملThe dimensional accuracy of polyvinyl siloxane impression materials using two different impression techniques: An in vitro study
AIM OF THE STUDY To evaluate and compare the linear dimensional changes of the three representative polyvinyl siloxane (PVS) impression materials and to compare the accuracy of single mix with double mix impression technique. METHODOLOGY A study mold was prepared according to revised American Dental Association specification number 19 for nonaqueous elastic dental impression materials. Three ...
متن کاملComparative evaluation of dimensional accuracy of different polyvinyl siloxane putty-wash impression techniques-in vitro study.
BACKGROUND Dimensional accuracy when making impressions is crucial to the quality of fixed prosthodontic treatment, and the impression technique is a critical factor affecting this accuracy. The purpose of this in vitro study was to compare the dimensional accuracy of the casts obtained from one step double mix, two step double mix polyvinyl siloxane putty- wash impression techniques using thre...
متن کاملDimensional stability of polyvinyl siloxane impression material reproducing the sulcular area.
The dimensional stability of a thin intra sulcular impression material reproducing the preparation finish line was evaluated. Impressions were taken of a stainless-steel master model of a simulated abutment with a 'gingival sulcus' using Express regular, Express fast and Aquasil. The putty-wash two-step technique was applied with spacer thicknesses of 0.5, 1 and 1.5 mm. Mid mesiodistal and bucc...
متن کاملA comparison of the accuracy and dimensional stability between two silicon impression materials (Speedex and Irasil)
A comparison of the accuracy and dimensional stability between two silicon impression materials (Speedex and Irasil) Dr. M. Sabouhi* - Dr. M. Dakhilalian** - Dr. N. Nehchiri*** *- Assistant Professor of Fixed Prosthodontics Dept. - Faculty of Dentistry – Isfahan University of Medical Sciences. **- Member of Fixed Prosthodontics Dept. - Faculty of Dentistry – Isfahan University of Medical Scienc...
متن کاملLinear dimensional stability of elastomeric impression materials over time.
UNLABELLED The purpose of this study was to evaluate the linear dimensional stability of different elastomeric impression materials over time. A metal mold was designed with its custom trays, which were made of thermoplastic sheets (Sabilex sheets 0.125 mm thick). Three impressions were taken of it with each of the following: the polyvinylsiloxane Examix-GC-(AdEx), Aquasil-Dentsply-(AdAq) and P...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of dental biomaterialsجلد ۲، شماره ۴، صفحات ۱۵۵-۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023