dimensional stability of polyether, alginate, and silicone impression materials after disinfection with 2% sanosil through the immersion technique

نویسندگان

alireza izadi department of prosthodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (hamadan university of medical sciences)

sina badamchizadeh school of dentistry, hamadan university of medical sciences, hamadan, ir iran; school of dentistry, hamadan university of medical sciences, hamadan, ir iran. tel: +98-9141040623, fax: +98-8138380509سازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (hamadan university of medical sciences)

hanieh mojaver kahnamouyi department of endodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (hamadan university of medical sciences)

hojat marefat private practice, hamadan, ir iran

چکیده

background to prevent diseases transmission, infection control in dental offices without reducing the accuracy and dimensional stability of impression materials is very important. objectives the aim of this study was to evaluate the effects of sanosil disinfectants on the dimensional stability of some usual impression materials. materials and methods three types of impression material, namely, alginate, condensational silicone, and polyether, were used in this study. impressions were obtained from the master steel model. fifteen impressions of each material (control group) were immersed in water for ten minutes and impressions of study groups were disinfected by immersion in 2% sanosil for ten minutes. then impressions were poured by type iii gypsum according to the manufacture's instruction. dimensions of casts in the two anterior dimensions, i.e. interval between the anterior abutments and interval between anterior-posterior abutments, were recorded by a digital caliper with the accuracy of 0.01 mm. data were analyzed with spss through two-way anova test. results the results showed that there was no significant difference in the mean dimension of casts prepared by different impression materials in anterior and anterior-posterior dimensions in comparison to the original model after disinfection with sanosil. conclusions the study revealed that disinfection with 2% sanosil has no significant effect on casts dimensions of alginate, silicone, and polyether impression and dimensional stability is maintained.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of prolonged storage and disinfection on the dimensional stability of 5 vinyl polyether silicone impression materials

PURPOSE Vinyl polyether silicone (VPES) has a different composition from other elastomeric impression materials as it combines vinyl polysiloxane (VPS) and polyether (PE). Therefore, it is important to study its properties and behavior under different test conditions. This study investigated the dimensional stability of 5 VPES consistencies when stored for up to 2 weeks, with and without using ...

متن کامل

Dimensional stability of alginate impression materials.

Introduction: In 2001, Cavex presented the first test results, which showed 5 days dimensional stability for Cavex ColorChange. More than 10 years we used this information to show our customers the high quality and stability of our products. In the meantime, our Research & Development department worked on improvements of the alginate impression materials. We formed close cooperation’s with supp...

متن کامل

the effect of disinfection with sodium hypochlorite 0.5% on dimensional stability of condensation silicone impression materials of speedex and irasil

statement of the problem: impression materials are concerned as a significant source of cross-contamination because of exposure to blood and saliva. purpose: considering the importance of infection control in the dental environments, this study is performed to investigate the dimensional changes of two condensation silicone impression materials, speedex and irasil, after immersion in 0.5% sodiu...

متن کامل

in vitro evaluation of dimensional stability of alginate impressions after disinfection by spray and immersion methods

background and aims. the most common method for alginate impression disinfection is spraying it by disinfecting agents, but some studies have shown that these impressions can be immersed, too. the aim of this study was to evaluate the dimensional stability of alginate impressions following disinfecting by spray and immersion methods. materials and methods. four common disinfecting agents (sodiu...

متن کامل

The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials.

The aim of this study was to determine the effect of immersion disinfection procedures on the dimensional stability of two elastomeric impression materials. Impressions of a stainless steel die were made with polyether (PE) and with addition-polymerized silicone rubber (PVS). The test specimens underwent disinfection treatment by immersion in two commercially available solutions containing quat...

متن کامل

Viscoelastic properties of silicone, polysulfide, and polyether impression materials.

The viscoelastic properties of nine silicone-, polysulfide-, and polyether-based impression materials were determined using creep tests. During deformation the materials demonstrated linear viscoelastic behavior. The creep compliance curves, recovery, and percent set were calculated. Permanent deformation in these materials is a result of lack of recovery of elastic deformation as well as visco...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
avicenna journal of dental research

جلد ۶، شماره ۲، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023