comparison of intertrochanteric fracture fixation with dynamic hip screw and bipolar hemiarthroplasty techniques

نویسندگان

mohammad emami department of orthopedic surgery, shahid beheshti uni- versity of medical sciences, tehran, iran.

ali reza manafi department of orthopedic surgery, shahid beheshti uni- versity of medical sciences, tehran, iran.

behroz hashemi department of orthopedic surgery, shahid beheshti university of medical sciences, tehran, iran.

ali nemati department of orthopedic surgery, shahid beheshti uni- versity of medical sciences, tehran, iran.

چکیده

background: at present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. the aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (dhs) and bipolar hemiarthroplasty in elderly patients with background medical conditions. methods: in this randomized clinical trial, 60 patients with intertrochanteric fractures, who were 45-60 years old, were randomly divided into dhs and bipolar groups. after treatment, the two groups were compared in relation to complications and mortality rates, functional status using the harris hip score (hhs), range of movement and severity of pain using the visual analogue score (vas). results: hhs (86±9 vs. 75±7.6), range of flexion (105±11 degrees vs. 90±17 degrees) and external rotation (35±7 degrees vs. 20±7 degrees) were significantly higher in the bipolar group compared to the dhs group (p<0.05). however, there were no significant differences in pain severity between the two groups. conclusion: reduction of intertrochanteric fractures in elderly patients with background medical conditions is more effective and less problematic with the bipolar technique compared to dhs and is better tolerated by patients, because this technique is associated with improvements in functional status and hip joint movement range.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques

Background: At present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. The aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (DHS) and bipolar hemiarthroplasty in elderly patients with background medical conditions. Methods: In this randomi...

متن کامل

Comparison of intertrochanteric fracture fixation with dynamic hip screw and bipolar hemiarthroplasty techniques.

BACKGROUND At present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. The aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (DHS) and bipolar hemiarthroplasty in elderly patients with background medical conditions. METHODS In this randomi...

متن کامل

Results of Intertrochanteric Fractures Fixed with Dynamic Hip Screw Fixation

Numerous internal fixation devices have been used to stabilize intertrochanteric fracturesWe have analyzed the results of the intertrochanteric fractures treated with dynamic hip screw fixation. 33 patients (13 males, 20 females) were included. Range of age was 50-90 years, right side involved in 21 cases whereas left side in 12 cases and classified according to Boyd and griffin classification ...

متن کامل

Dynamic hip screw blade fixation for intertrochanteric hip fractures.

PURPOSE To assess the one-year outcome of a dynamic hip screw (DHS) blade in the treatment of AO/OTA 31-A1 and 31-A2 intertrochanteric hip fractures. METHODS 35 men and 65 women aged 47 to 100 (mean, 83) years underwent fixation with a DHS blade for A1 (n=47) and A2 (n=53) intertrochanteric hip fractures after a low-energy injury. Patients were operated on within 48 hours of admission. Antero...

متن کامل

Salvage of failed dynamic hip screw fixation of intertrochanteric fractures.

Twenty-six patients with failed dynamic hip screw fixation of intertrochanteric fractures were included in this study. The mean age of the patients was 61 years (range, 38-84 years). Average limb shortening was 2.4 cm; 18 patients were treated with revision internal fixation and eight patients with prosthetic replacement. The decision depended on the physiological age of the patient, quality of...

متن کامل

Pseudoaneurysm and intramuscular haematoma after dynamic hip screw fixation for intertrochanteric femoral fracture: a case report.

We report the case of an 83-year-old woman who developed a pseudoaneurysm of the profunda femoris artery after dynamic hip screw fixation for an intertrochanteric femoral fracture. 23 days after the fixation, radiological investigations including colour Doppler ultrasonography and computed tomographic angiography identified a pseudoaneurysm surrounded by a large intramuscular haematoma close to...