sonographic optic nerve sheath diameter as a screening tool for detection of elevated intracranial pressure

نویسندگان

afshin amini associate professor of emergency medicine

razieh eghtesadi

ali mohammad feizi

behnam mansouri

چکیده

introduction: timely diagnosis and treatment of post traumatic, elevated intracranial pressure (eicp), could reduce morbidity and mortality, as well as improve patients’ outcome. this study is trying to evaluate the diagnostic accuracy of sonographic optic nerve sheath diameter (onsd) in detection of eicp. methods: sonographic onsd of patients with head trauma or cerebrovascular accident suspicious for eicp were evaluated by a trained chief resident of emergency medicine, who was blind to the clinical and brain computed tomography scan (bct) findings of patients. immediately after ultrasonography, bct was performed and reported by an expert radiologist without awareness from other results of the patients. finally, ultrasonographic and bct findings regarding eicp were compared. to evaluate the ability of sonographic onsd in predicting the bct findings and obtain best cut-off level, receiver operating characteristic (roc) curve were used. sensitivity, specificity, positive predictive value (ppv), negative predictive value (npv), positive likelihood ratio (plr), and negative likelihood ratio (nlr) of sonographic onsd in determining of eicp was calculated. p < 0.05 was considered to be statistically significant. results: there were 222 patients (65.3% male), with mean age of 42.2±19.5 years (range: 16-90 years). bct showed signs of eicp, in 28 cases (12.6%). the means of the onsd in the patients with eicp and normal icp were 5.5 ± 0.56 and 3.93 ± 0.53 mm, respectively (p<0.0001). roc curve demonstrated that the best cut off was 4.85 mm. sensitivity, specificity, ppv, npv, plr, and nlr of onsd for prediction of eicp were 96.4%, 95.3%, 72.2%, 98.9%, 20.6, and 0.04, respectively. conclusion: sonographic diameter of optic nerve sheath could be considered as an available, accurate, and noninvasive screening tool in determining the elevated intracranial pressure in cases with head trauma or cerebrovascular accident.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sonographic Optic Nerve Sheath Diameter as a Screening Tool for Detection of Elevated Intracranial Pressure

INTRODUCTION Timely diagnosis and treatment of post-traumatic elevated intracranial pressure (EICP) could be reduced morbidity and mortality, and improved patients' outcome. This study is trying to evaluate the diagnostic accuracy of sonographic optic nerve sheath diameter (ONSD) in detection of EICP. METHODS Sonographic ONSD of patients with head trauma or cerebrovascular accident suspicious...

متن کامل

Optic Nerve Sheath Diameter as a Bedside Assessment for Elevated Intracranial Pressure

A previously fit and healthy 26-year-old lady with no significant medical history presented with a two-month history of headaches. The headaches were prolonged, generalised, and unusually severe for the patient. Examination revealed papilloedema. The patient's optic nerve sheath diameter was measured 3 mm posterior to the globe and found to be 7.5 mm. The patient subsequently had computed tomog...

متن کامل

Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure

INTRODUCTION The accurate diagnosis of elevated intracranial pressure (eICP) in the emergent setting is a critical determination that presents significant challenges. Several studies show correlation of sonographic optic nerve sheath diameter (ONSD) to eICP, while others show high inter-observer variability or marginal performance with less experienced sonographers. The objective of our study i...

متن کامل

Sonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position

BACKGROUND It remains to be elucidated whether the Trendelenburg position increases intracranial pressure (ICP). ICP can be evaluated by measuring the sonographic optic nerve sheath diameter (ONSD). We investigated the effect of the isolated Trendelenburg position on ONSD in patients undergoing robot-assisted laparoscopic radical prostatectomy. Additionally, we evaluated the effect of the Trend...

متن کامل

Bedside sonographic measurement of optic nerve sheath diameter as a predictor of increased intracranial pressure in children.

STUDY OBJECTIVE We investigate the test performance of emergency physician-performed sonographic measurement of optic nerve sheath diameter for diagnosis of increased intracranial pressure. METHODS Children between the ages of 0 and 18 years with suspected increased intracranial pressure were prospectively recruited from the emergency department and ICU of an urban, tertiary-level, freestandi...

متن کامل

Accuracy of Noninvasive Intraocular Pressure or Optic Nerve Sheath Diameter Measurements for Predicting Elevated Intracranial Pressure in Cryptococcal Meningitis

BACKGROUND Cryptococcal meningitis is associated with increased intracranial pressure (ICP). Therapeutic lumbar puncture (LP) is recommended when the initial ICP is >250 mm H2O, yet the availability of manometers in Africa is limited and not always used where available. We assessed whether intraocular pressure could be a noninvasive surrogate predictor to determine when additional therapeutic L...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
emergency journal

جلد ۱، شماره ۱، صفحات ۱۵-۱۹

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023