accuracy of ultrasonography in confirmation of adequate reduction of distal radius fractures

نویسندگان

mehrdad esmailian department of emergency medicine, isfahan university of medical sciences, isfahan, iran

ehsan haj zargarbashi department of emergency medicine, isfahan university of medical sciences, isfahan, iran

babak masoumi department of emergency medicine, isfahan university of medical sciences, isfahan, iran

mehdi karami department of radiology, isfahan university of medical sciences, isfahan, iran

چکیده

introduction: restoration of normal anatomic alignment is a key component of the treatment of distal radius fractures (drf). this study aimed to evaluate the accuracy of ultrasonography (us) in determining the adequacy of closed reduction in these fractures. methods : drf patients admitted to the emergency department of al-zahra hospital, isfahan, iran from september 2011 to 2012, were enrolled. after closed reduction, the adequacy was investigated through both us and control plain radiography. then, sensitivity, specificity, positive and negative predicative values of us in confirmation of closed reduction was evaluated. also inter-rater agreement between the two diagnostic tools was analyzed by calculating cohen’s kappa coefficient. results: finally, 154 patients were evaluated (females: 53.9%) with mean age of 40.03±14.7 (range: 22-73). us had sensitivity, specificity, positive and negative predictive value of 99.3% (95%ci: 96.2-99.9), 100.0% (95%ci: 62.9-100.0), 100.0% (95%ci: 97.5-100.0), and 88.9% (95%ci: 51.7-98.1) in confirmation of the adequate reduction, respectively. in addition, inter-rater reliability was 0.94 (95%ci: 0.89-0.99; p<0.0001). conclusion : it seems that us could be considered as a highly sensitive, accurate, easy to use, noninvasive and safe tool for guidance and confirming of closed reduction in drf.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Ultrasonography in Confirmation of Adequate Reduction of Distal Radius Fractures

INTRODUCTION Restoration of normal anatomic alignment is a key component of the treatment of distal radius fractures (DRF). This study aimed to evaluate the accuracy of ultrasonography (US) in determining the adequacy of closed reduction in these fractures. METHODS DRF patients admitted to the emergency department of Al-Zahra Hospital, Isfahan, Iran from September 2011 to 2012, were enrolled....

متن کامل

ultrasound-guided reduction of distal radius fractures

introduction: distal radius fractures are a common traumatic injury, particularly in the elderly population. in the present study we examined the effectiveness of ultrasound guidance in the reduction of distal radius fractures in adult patients presenting to emergency department (ed). methods: in this prospective case control study, eligible patients were adults older than 18 years who presente...

متن کامل

Comparison of close reduction and percutaneous pin fixation as treatments for distal metaphyseal radius fractures

Background: Distal radius fractures are one of the most common fractures of skeletal system and because of the aging of population, its incidence is rising. The aim of the present research was to evaluate the close reduction and percutaneous pin fixation as a treatment option. Material and methods: 44 patients who were type 2 according to universal classification or type 2 or 3 according to Ol...

متن کامل

Ultrasound-Guided Reduction of Distal Radius Fractures

BACKGROUND Ultrasound (US) may provide the emergency physician with the ability to do real-time assessment of fracture reduction adequacy. OBJECTIVES To assess whether US guidance aids in determining the adequacy of distal radius fracture reduction in the emergency department (ED), and to compare the rates of successful reduction with and without US. METHODS We conducted a prospective study...

متن کامل

synthesis of 3-aryl-2h-benzo[b]-1,4-oxazines in [omim]bf4 and reduction of organic compounds in methylimidazolium formate

در این پروژه ترکیبات 3-آریل-2h-بنزو[b]-4،1-اکسازین ها از مواد اولیه تجاری مشتقات دو آمینو فنول و ?-هالو کتون های آروماتیک در مایع یونی 1-اکتیل-3-متیل ایمیدازولیوم تترا فلورو بورات([omim]bf4) سنتز شده است. این واکنش توسط باز پتاسیم کربنات محلول از طریق o-آلکیلاسیون و سپس یک واکنش آمیداسیون درون مولکولی خود بخود در مدت زمان کوتاه انجام می شود. ترکیبات 4،1-بنزوکسازین به این روش با بهره خوب تا آلی ...

15 صفحه اول

Anatomical reduction of intra-articular fractures of the distal radius.

We treated 31 intra-articular fractures of the distal radius by arthroscopically-assisted reduction and percutaneous fixation with Kirschner (K-) wires. Tears of the triangular fibrocartilage (58 %), scapholunate (85 %) and lunotriquetral (61%) instability and osteochondral lesions (19%) were also treated. A total of 26 patients was independently reviewed at an average of 19 months. The mean pa...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
emergency journal

جلد ۱، شماره ۱، صفحات ۷-۱۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023