diagnostic accuracy of optic nerve ultrasonography and ophthalmoscopy in prediction of elevated intracranial pressure

نویسندگان

keihan golshani department of emergency medicine, alzahra hospital, isfahan university of medical sciences, isfahan, iran

mehdi ebrahim zadeh department of emergency medicine, nemazi hospital, shiraz university of medical sciences, shiraz, iran

ziba farajzadegan community medicine department, faculty of medicine, isfahan university of medical sciences, isfahan, iran

fariborz khorvash isfahan neurosciences research center, isfahan university of medical sciences, isfahan, iran

چکیده

introduction: elevated intracranial pressure (icp) is a major and potentially lethal disorder in patients admitted to the emergency department (ed). several methods are being used to investigate for elevated icp. here we assessed and compared the diagnostic accuracy of two existing tools of ophthalmoscopy and optic nerve ultrasonography in detection of elevated icp. methods: 131 participants with probable elevation of icp referred to the emergency department of al-zahra hospital, isfahan, iran, from 2012 to 2014, were enrolled. brain computed tomography (ct) scan, ultrasonography of optic nerve sheath, and ophthalmoscopy were performed for them. the optic nerves sheath with diameter more than 5 millimeters was considered as elevated icp. widening of optic nerve, ocular venous engorgement, blurring, hemorrhage over optic disk, elevation of optic disk, and retinal venous tortuosity were recorded as evidences of icp rising in ophthalmoscopy. diagnostic accuracy of the two tools in prediction of icp rising were compared with the results of brain ct scan as a gold standard. results: the mean age of participants was 46.29 ± 10 years (77% male). the number of diagnosed elevated icps with ophthalmoscopy and ultrasound were 98 (74.8%) and 102 (77.9%) cases, respectively. the calculated sensitivity and specificity of ophthalmoscopy and ultrasonography in detection of icp rising were 100.0% (95% ci: 88.6-100.0) and 35.4% (95% ci: 26.0-46.2), 100.0% (95% ci: 84.0-100.0) and 31.9% (95% ci: 23.0-41.7), respectively. conclusion: the present study reveals that bedside ultrasonography of optic nerve sheath and ophthalmoscopy have enough accuracy for screening of patients with probable elevation of icp. of course, it should be considered that despite of high sensitivity of both tools, their specificity is low.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Accuracy of Optic Nerve Ultrasonography and Ophthalmoscopy in Prediction of Elevated Intracranial Pressure

INTRODUCTION Elevated intracranial pressure (ICP) is a major and potentially lethal disorder in patients admitted to the emergency department (ED). Several methods are being used to investigate for elevated ICP. Here we assessed and compared the diagnostic accuracy of two existing tools of ophthalmoscopy and optic nerve ultrasonography in detection of elevated ICP. METHODS 131 participants wi...

متن کامل

Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath.

UNLABELLED Patients with altered level of consciousness may be suffering from elevated intracranial pressure (EICP) from a variety of causes. A rapid, portable, and noninvasive means of detecting EICP is desirable when conventional imaging methods are unavailable. OBJECTIVES The hypothesis of this study was that ultrasound (US) measurement of the optic nerve sheath diameter (ONSD) could accur...

متن کامل

sonographic optic nerve sheath diameter as a screening tool for detection of elevated intracranial pressure

introduction: timely diagnosis and treatment of post traumatic, elevated intracranial pressure (eicp), could reduce morbidity and mortality, as well as improve patients’ outcome. this study is trying to evaluate the diagnostic accuracy of sonographic optic nerve sheath diameter (onsd) in detection of eicp. methods: sonographic onsd of patients with head trauma or cerebrovascular accident suspic...

متن کامل

Accuracy of Noninvasive Intraocular Pressure or Optic Nerve Sheath Diameter Measurements for Predicting Elevated Intracranial Pressure in Cryptococcal Meningitis

BACKGROUND Cryptococcal meningitis is associated with increased intracranial pressure (ICP). Therapeutic lumbar puncture (LP) is recommended when the initial ICP is >250 mm H2O, yet the availability of manometers in Africa is limited and not always used where available. We assessed whether intraocular pressure could be a noninvasive surrogate predictor to determine when additional therapeutic L...

متن کامل

Imaging intracranial pressure: an introduction to ultrasonography of the optic nerve sheath.

I N clinical practice it is important to determine whether increased intracranial pressure is present. This allows one to alter hemodynamic management, predict the potential for neurologic deterioration, and guide therapeutic removal of cerebrospinal fluid or avoid such withdrawal. A spinal leak or drainage of cerebrospinal fluid can create an imbalance between supratentorial and infratentorial...

متن کامل

Using MRI of the optic nerve sheath to detect elevated intracranial pressure

The current gold standard for the diagnosis of elevated intracranial pressure (ICP) remains invasive monitoring. Given that invasive monitoring is not always available or clinically feasible, there is growing interest in non-invasive methods of assessing ICP using diagnostic modalities such as ultrasound or magnetic resonance imaging (MRI). Increased ICP is transmitted through the cerebrospinal...