diagnostic accuracy of ultrasonography and radiography in detection of pulmonary contusion; a systematic review and meta-analysis

نویسندگان

mostafa hosseini 1- sina trauma and surgery research center, tehran university medical sciences, tehran, iran. 2- department of epidemiology and biostatistics, school of public health, tehran university of medical sciences, tehran, iran.

parisa ghelichkhani department of intensive care nursing, school of nursing and midwifery, tehran university of medical sciences, tehran, iran

masoud baikpour department of medicine, school of medicine, tehran university of medical sciences, tehran, iran

abbas tafakhori 1- department of neurology, school of medicine, imam khomeini hospital, tehran university of medical sciences, tehran, iran. 2- iranian center of neurological research, tehran university of medical sciences, tehran, iran.

چکیده

introduction: ultrasonography is currently being used as one of the diagnostic modalities in various medical emergencies for screening of trauma patients. the diagnostic value of this modality in detection of traumatic chest injuries has been evaluated by several studies but its diagnostic accuracy in diagnosis of pulmonary contusion is a matter of discussion. therefore, the present study aimed to determine the diagnostic accuracy of ultrasonography and radiography in detection of pulmonary contusion through a systematic review and meta-analysis. methods: an extended systematic search was performed by two reviewers in databases of medline, embase, isi web of knowledge, scopus, cochrane library, and proquest. they extracted the data and assessed the quality of the studies. after summarization of data into true positive, false positive, true negative, and false negative meta-analysis was carried out via a mixed-effects binary regression model. further subgroup analysis was performed due to a significant heterogeneity between the studies. results: 12 studies were included in this meta-analysis (1681 chest trauma patients, 76% male). pooled sensitivity of ultrasonography in detection of pulmonary contusion was 0.92 (95% ci: 0.81-0.96; i2= 95.81, p<0.001) and its pooled specificity was calculated to be 0.89 (95% ci: 0.85-0.93; i2 = 67.29, p<0.001) while these figures for chest radiography were 0.44 (95% ci: 0.32-0.58; i2= 87.52, p<0.001) and 0.98 (95% ci: 0.88-1.0; i2= 95.22, p<0.001), respectively. subgroup analysis showed that the sources of heterogeneity between the studies were sampling method, operator, frequency of the transducer, and sample size. conclusion: ultrasonography was found to be a better screening tool in detection of pulmonary contusion. moreover, an ultrasonography performed by a radiologist / intensivist with 1-5mhz probe has a higher diagnostic value in identifying pulmonary contusions.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Accuracy of Ultrasonography and Radiography in Detection of Pulmonary Contusion; a Systematic Review and Meta-Analysis

INTRODUCTION Ultrasonography is currently being used as one of the diagnostic modalities in various medical emergencies for screening of trauma patients. The diagnostic value of this modality in detection of traumatic chest injuries has been evaluated by several studies but its diagnostic accuracy in diagnosis of pulmonary contusion is a matter of discussion. Therefore, the present study aimed ...

متن کامل

application of ultrasonography and radiography in detection of hemothorax: a systematic review and meta-analysis

introduction: hemothorax is one of the most prevalent injuries caused by thoracic traumas. early detection and treatment of this injury is of utmost importance in prognosis of the patient, but there are still controversial debates on the diagnostic value of imaging techniques in detection of hemothorax. therefore, the present study aimed to evaluate the diagnostic value of chest ultrasonography...

متن کامل

comparison of ultrasonography and radiography in detection of thoracic bone fractures; a systematic review and meta-analysis

introduction: the potential benefit of ultrasonography for detection of thoracic bone fractures has been proven in various surveys but no comprehensive conclusion has been drawn yet; therefore, the present study aimed to conduct a thorough meta-analytic systematic review on this subject. methods: two reviewers independently carried out a comprehensive systematic search in medline, embase, isi w...

متن کامل

a contrastive analysis of concord and head parameter in english and azerbaijani

این پایان نامه به بررسی و مقایسه دو موضوع مطابقه میان فعل و فاعل (از نظر شخص و مشار) و هسته عبارت در دو زبان انگلیسی و آذربایجانی می پردازد. اول رابطه دستوری مطابقه مورد بررسی قرار می گیرد. مطابقه به این معناست که فعل مفرد به همراه فاعل مفرد و فعل جمع به همراه فاعل جمع می آید. در انگلیسی تمام افعال، بجز فعل بودن (to be) از نظر شمار با فاعلشان فقط در سوم شخص مفرد و در زمان حال مطابقت نشان میدهند...

15 صفحه اول

Application of Ultrasonography and Radiography in Detection of Hemothorax; a Systematic Review and Meta-Analysis

INTRODUCTION Hemothorax is one of the most prevalent injuries caused by thoracic traumas. Early detection and treatment of this injury is of utmost importance in prognosis of the patient, but there are still controversial debates on the diagnostic value of imaging techniques in detection of hemothorax. Therefore, the present study aimed to evaluate the diagnostic value of chest ultrasonography ...

متن کامل

Diagnostic Accuracy of Chest Ultrasonography versus Chest Radiography for Identification of Pneumothorax: A Systematic Review and Meta-Analysis

BACKGROUND Early detection of pneumothorax is critically important. Several studies have shown that chest ultrasonography (CUS) is a highly sensitive and specific tool. The present systematic review and meta-analysis was designed to evaluate the diagnostic accuracy of CUS and chest radiography (CXR) for detection of pneumothorax. MATERIALS AND METHODS The literature search was conducted using...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
emergency journal

جلد ۳، شماره ۴، صفحات ۱۲۷-۱۳۶

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023