introduction : confirmation of proper endotracheal tube placement is one of the most important and lifesaving issues of tracheal intubation. the present study was aimed to evaluate the accuracy of tracheal ultrasonography by emergency residents in this regard. method : this was a prospective, cross sectional study for evaluating the diagnostic accuracy of ultrasonography in endotracheal tube placement confirmation compared to a combination of 4 clinical confirmation methods of chest and epigastric auscultation, direct laryngoscopy, aspiration of the tube, and pulse oximetry (as reference test). results : 150 patients with the mean age of 58.52 ± 1.73 years were included (56.6% male). sensitivity, specificity, positive predictive value, negative predictive value, and positive and negative likelihood ratio of tracheal ultrasonography in endotracheal tube confirmation were 96 (95% ci: 92-99), 88 (95% ci: 62-97), 98 (95% ci: 94-99), 78 (95% ci: 53-93), 64 (95% ci: 16-255), and 0.2 (95% ci: 0.1-0.6), respectively. conclusion : the present study showed that tracheal ultrasonography by trained emergency medicine residents had excellent sensitivity (>90%) and good specificity (80-90) for confirming endotracheal tube placement. therefore, it seems that ultrasonography is a proper screening tool in determining endotracheal tube placement.
منابع مشابه
Screening Characteristics of Bedside Ultrasonography in Confirming Endotracheal Tube Placement; a Diagnostic Accuracy Study
INTRODUCTION Confirmation of proper endotracheal tube placement is one of the most important and lifesaving issues of tracheal intubation. The present study was aimed to evaluate the accuracy of tracheal ultrasonography by emergency residents in this regard. METHOD This was a prospective, cross sectional study for evaluating the diagnostic accuracy of ultrasonography in endotracheal tube plac...
متن کاملWhere's the tube? Evaluation of hand-held ultrasound in confirming endotracheal tube placement.
INTRODUCTION The diagnosis of endotracheal tube (ETT) mal-position may be delayed in extreme environments. Several methods are utilized to confirm proper ETT placement, but these methods can be unreliable or unavailable in certain settings. Thoracic sonography, previously utilized to detect pneumothoraces, has not been tested to assess ETT placement. HYPOTHESIS Thoracic sonography could corre...
متن کاملBedside Ultrasonography for Early Diagnosis of Occult Radial Head Fractures in Emergency Room: A CTComparative Diagnostic Study
Background: Some of the Mason type I fractures cannot be detected on early radiographic images. These occultfractures are considered as a diagnostic challenge for physicians. Our aim was to determine the value of bedsideultrasonography for the detection of Mason I radial head fractures that are non-visible in early X-ray’s.Methods: A prospective blind single-center diagnostic study was conducte...
متن کاملEmergency Department Bedside Ultrasonography for Diagnosis of Acute Cholecystitis; a Diagnostic Accuracy Study
Introduction Using bedside ultrasound in diagnosing acute cholecystitis in the emergency department (ED) can save time, help the decision making process and allocate resources wisely. This study aimed to evaluate the diagnostic accuracy of bedside right upper quadrant (RUQ) ultrasonography in detection of acute cholecystitis. Method In this diagnostic accuracy study, patients presenting to ED...
متن کاملscreening characteristics of timi score in predicting acute coronary syndrome outcome; a diagnostic accuracy study
introduction: in cases with potential diagnosis of ischemic chest pain, screening high risk patients for adverse outcomes would be very helpful. the present study was designed aiming to determine the diagnostic accuracy of thrombolysis in myocardial infarction (timi) score in patients with potential diagnosis of ischemic chest pain. method: this diagnostic accuracy study was designed to evaluat...
متن کاملInflating the endotracheal tube cuff with saline to confirm correct depth using bedside ultrasonography.
Although bedside ultrasonography can accurately distinguish esophageal from tracheal intubation, it is not used to establish the correct depth of endotracheal tube insertion. As indirect sonographic markers of endotracheal tube insertion depth have proven unreliable, a method for visual verification of correct tube depth would be ideal. We describe the use of saline to inflate the endotracheal ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
emergency journalجلد ۴، شماره ۰۹، صفحات ۰-۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023