introduction: designing a tool that can differentiate those at risk of child abuse with great diagnostic accuracy is of great interest. the present study was designed to evaluate the diagnostic accuracy of escape instrument in triage of at risk cases of child abuse presenting to emergency department (ed). methods: the present diagnostic accuracy study performed on 6120 of the children under 16 years old presented to ed during 3 years, using convenience sampling. confirmation by the child abuse team (pediatrician, a socialworker, and a forensic physician) was considered as the gold standard. screening performance characteristics of escape were calculated using stata 21. results: 6120 children with the mean age of 2.19 § 1.12 years were screened (52.7% girls). 137 children were suspected victims of child abuse. based on child abuse team opinion, 35 (0.5%) children were confirmed victims of child abuse. sensitivity, specificity, positive and negative likelihood ratio and positive and negative predictive values of this test with 95% ci were 100 (87.6 – 100), 98.3 (97.9 – 98.6), 25.5 (18.6 – 33.8), 100 (99.9 – 100), 0.34 (0.25 – 0.46), and 0 (0 – nan), respectively. area under the roc curve was 99.2 (98.9 – 99.4). conclusion: it seems that escape is a suitable screening instrument for detection of at risk cases of child abuse presenting to ed. based on the results of the present study, the accuracy of this screening tool is 99.2%, which is in the excellent range.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Potential Child Abuse Screening in Emergency Department; a Diagnostic Accuracy Study

INTRODUCTION Designing a tool that can differentiate those at risk of child abuse with great diagnostic accuracy is of great interest. The present study was designed to evaluate the diagnostic accuracy of Escape instrument in triage of at risk cases of child abuse presenting to emergency department (ED). METHOD The present diagnostic accuracy study performed on 6120 of the children under 16 y...

متن کامل

Facilitators and barriers to screening for child abuse in the emergency department

BACKGROUND To identify facilitators of, and barriers to, screening for child abuse in emergency departments (ED) through interviews with ED staff, members of the hospital Board, and related experts. METHODS This qualitative study is based on semi-structured interviews with 27 professionals from seven Dutch hospitals (i.e. seven pediatricians, two surgeons, six ED nurses, six ED managers and s...

متن کامل

Value of systematic detection of physical child abuse at emergency rooms: a cross-sectional diagnostic accuracy study

OBJECTIVES The aim of our diagnostic accuracy study Child Abuse Inventory at Emergency Rooms (CHAIN-ER) was to establish whether a widely used checklist accurately detects or excludes physical abuse among children presenting to ERs with physical injury. DESIGN A large multicentre study with a 6-month follow-up. SETTING 4 ERs in The Netherlands. PARTICIPANTS 4290 children aged 0-7 years at...

متن کامل

Prediction of child abuse risk from emergency department use.

OBJECTIVE To examine whether pre-abuse rates and patterns of emergency department (ED) visits between children with supported child abuse and age-matched control subjects are useful markers for abuse risk. STUDY DESIGN A population-based case-control study using probabilistic linkage of four statewide data sets. Cases were abused children <13 years of age, identified between January 1, 2002, ...

متن کامل

Emergency Department Bedside Ultrasonography for Diagnosis of Acute Cholecystitis; a Diagnostic Accuracy Study

Introduction Using bedside ultrasound in diagnosing acute cholecystitis in the emergency department (ED) can save time, help the decision making process and allocate resources wisely. This study aimed to evaluate the diagnostic accuracy of bedside right upper quadrant (RUQ) ultrasonography in detection of acute cholecystitis. Method In this diagnostic accuracy study, patients presenting to ED...

متن کامل

Diagnostic Accuracy of Acute Appendicitis by Ultrasound in Hospital Emergency

Background Acute appendicitis is the most common medical condition requiring immediate abdominal surgery.Medical ultrasound is a non-intrusive, non-expensive and available diagnostic method. In this study, the accuracy of ultrasound in diagnosis of acute appendicitis in hospital emergency was evaluated. Materials and Methods This retrospective cohort study was performed at Ahvaz Imam Khomeini h...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
emergency journal

جلد ۴، شماره ۰۹، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023