echocardiographic assessment of left ventricular twisting and untwisting rate in normal subjects by tissue doppler and velocity vector imaging: comparison of two methods
نویسندگان
چکیده
conclusions results suggest that these methods cannot be interchanged, and vvi showed significantly lower lv peak twist, peak twisting rate and peak untwisting rate. however, when lv twist and lv twisting rates were normalized to lv length, values were comparable for both imaging techniques. results twist degree was significantly lower in the vvi group than in the tdi group (p = 0.008, r = 0.56). lv torsion was lower in the vvi group but was not significant. (p = 0.13, r = 0.38). twisting rate (p = 0.004, r = 0.66) and untwisting rate (p = 0.0001, r = 0.61) were lower in the vvi group, but when timing of untwisting rate was normalized by systolic duration, there was no significant difference between the two groups (p = 0.41, r = 0.59). similarly, when peak untwisting rate was normalized by lv length, there was a significant decline in normalized peak untwisting rate in the vvi group (p = 0.004, r = 0.62), but not in peak twisting rate normalized by lv length (p = 0.12, r = 0.42). peak untwisting rate normalized by lv torsion was not statistically different between the two groups (p = 0.05, r = 0.53). objectives recent advances in echocardiography techniques have allowed for quantification of lv mechanics. the aim of the present study was to compare various lv twisting and untwisting parameters in healthy human subjects determined by velocity vector imaging (vvi) and tissue doppler imaging (tdi) at rest. patients and methods all volunteers (47 healthy subjects in two groups: 24 subjects in vvi group and 23 subjects in tdi group) underwent complete echocardiographic study, and lv torsional parameters were assessed by vvi or tdi methods. in addition, lv torsion and lv twisting/untwisting rate profiles were calculated throughout cardiac cycle. background the torsional parameters of the left ventricle (lv) are sensitive indicators of the cardiac performance. the torsion/twist of the lv is the wringing motion of the heart around its long axis created by oppositely directed apical and basal rotations and is determined by contracting myofibers in the lv wall which are arranged in opposite directions between the subendocardial and subepicardial layers. this motion is essential for regulating the lv systolic and diastolic functions.
منابع مشابه
Echocardiographic Assessment of Left Ventricle Torsion by Tissue Doppler and Velocity Vector Imaging
Introduction Left ventricular (LV) twist is believed to store potential energy and plays an important role in generating diastolic suction. Recent advances in echocardiography techniques have allowed quantification of LV twist. The aim of the present study was to compare LV twist and torsion in healthy human subjects determined by velocity vector imaging (VVI) and tissue Doppler imaging (TDI) a...
متن کاملechocardiographic assessment of left ventricle torsion by tissue doppler and velocity vector imaging
introduction left ventricular (lv) twist is believed to store potential energy and plays an important role in generating diastolic suction. recent advances in echocardiography techniques have allowed quantification of lv twist. the aim of the present study was to compare lv twist and torsion in healthy human subjects determined by velocity vector imaging (vvi) and tissue doppler imaging (tdi) a...
متن کاملEchocardiographic Assessment of Left Ventricle Torsion by Tissue Doppler and Velocity Vector Imaging
Introduction Left ventricular (LV) twist is believed to store potential energy and plays an important role in generating diastolic suction. Recent advances in echocardiography techniques have allowed quantification of LV twist. The aim of the present study was to compare LV twist and torsion in healthy human subjects determined by velocity vector imaging (VVI) and tissue Doppler imaging (TDI) a...
متن کاملassessment of deep word knowledge in elementary and advanced iranian efl learners: a comparison of selective and productive wat tasks
testing plays a vital role in any language teaching program. it allows teachers and stakeholders, including program administrators, parents, admissions officers and prospective employers to be assured that the learners are progressing according to an accepted standard (douglas, 2010). the problems currently facing language testers have both practical and theoretical implications but the first i...
comparison of blood flow velocity changes in posterior cerebral artery measured with transcranial doppler sonography in migraineurs with visual aura and normal persons after photostimulation
چکیده ندارد.
15 صفحه اولEchocardiographic assessment of left ventricular untwist rate: comparison of tissue Doppler and speckle tracking methodologies.
AIMS The study was designed to test the influence of the temporal resolution, at which tissue Doppler imaging (TDI) and speckle tracking imaging (STI) operate, on the accurate assessment of left ventricular (LV) untwist rate (UR). METHODS AND RESULTS Echo imaging and invasive LV pressure measurements were performed during right atrial (RA) pacing and dobutamine challenge in eight pigs. LV tor...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
archives of cardiovascular imagingجلد ۲، شماره ۳، صفحات ۰-۰
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023