a new sonographic phantom for quality control and training purposes

نویسندگان

ahmad bitarafan-rajabi echocardiography research center, rajaie cardiovascular medical and research center, iran university of medical sciences, tehran, ir iran

hadi hasanzadeh department of medical physics, semnan university of medical sciences, semnan, ir iran; department of medical physics, semnan university of medical sciences, semnan, ir iran. tel: +98-2333654171; ext: 525, fax: +98-2333654161

mahdi jahangiri department of medical physics, semnan university of medical sciences, semnan, ir iran

zohreh hoseinpour department of medical physics, semnan university of medical sciences, semnan, ir iran

چکیده

background evaluation of the accuracy and performance of sonography units needs tissue-mimicking phantoms. these phantoms play an important role by simulating soft tissues, obviating the need to experiment on humans or animals. objectives to present a simple sonographic phantom for quality control and training purposes. materials and methods the presented phantom consists of a two-part plexiglas box. the larger part is filled with a mixture of ethanol (9.5 ± 0.25%) in distilled water and a solution of sodium nitrite (0.1 m) to prevent rusting. the second part is filled with a combination of 3.85% by wt. % agar, and 50 g/l of powdered graphite as the background material. in this study, chrome-plated electric guitar strings, 0.52 mm in diameter, were used. several objects were considered as tissue-equivalent material, and their images were obtained at different times. criteria for the selection of suitable objects comprised similarity between the obtained image and the corresponding tissues in the human body, minimal shrinkage, and change in brightness level at different times. in addition to quantitative analysis obtained from image processing, a blind qualitative study was done by a radiologist. results both results of quantitative analysis using matlab software and independent qualitative analysis showed that the commercial rubber and agar were appropriate as solid and cystic objects, respectively. moreover, quantitative analysis done with matlab on images obtained from the phantom showed that the commercial rubber and agar had a 5% and 2% change in image pixel intensity (brightness) after 2 months, respectively. conclusions the presented phantom not only has lower cost and complexity, which make it suitable for educational centers, but also is capable of providing good images of cystic and solid objects for quality control and training purposes. furthermore, it confers reliable stability for at least 2 months, as was assessed in the present study.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Developing a Verification and Training Phantom for Gynecological Brachytherapy System

Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...

متن کامل

Synthesis, labeling and quality control of a new Neuropeptide Y analogue for diagnosis of breast tumors

  Introduction: Over expression of selected peptide receptors in human tumors has been shown to represent clinically relevant targets for cancer diagnosis and therapy. The aim of this work was to investigate Neuropeptide Y (NPY) as a new radiopharmaceutical for diagnosis of breast cancer. Methods: A neuropeptide Y analogues with Y1 receptor preference and agonistic p...

متن کامل

Evaluation of a new body composition phantom for quality control and cross-calibration of DXA devices.

This study evaluated a new body composition phantom and its use for quality control and cross-calibration of dual-energy X-ray absorptiometry (DXA) instruments for measurements of body composition. We imaged the variable composition phantom (Lunar, Madison, WI) on eight different DXA devices. Deviations of up to 7% fat were observed when we compared the percent fat values measured by the differ...

متن کامل

A novel phantom design for brachytherapy quality assurance

Background: One major challenge in brachytherapy is to verify the accuracy of dose distributions calculated by the treatment planning system. In this project, a new phantom design has been introduced for quality assurance of dose distributions in gynocological (GYN) brachytherapy implants using EBT GafChromic film. Materials and Methods: This phantom has been designed and fabricated from 90 sla...

متن کامل

Evaluation of a quality control phantom for digital chest radiography

RATIONALE AND OBJECTIVES To examine the effectiveness and suitability of a quality control (QC) phantom for a routine QC program in digital radiography. MATERIALS AND METHODS The chest phantom consists of copper and aluminum cutouts arranged to resemble the appearance of a chest. Performance of the digital radiography (DR) system is evaluated using high and low contrast resolution objects pla...

متن کامل

A Rotational Cylindrical fMRI Phantom for Image Quality Control

PURPOSE A novel phantom for image quality testing for functional magnetic resonance imaging (fMRI) scans is described. METHODS The cylindrical, rotatable, ~4.5L phantom, with eight wedge-shaped compartments, is used to simulate rest and activated states. The compartments contain NiCl2 doped agar gel with alternating concentrations of agar (1.4%, 1.6%) to produce T1 and T2 values approximating...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
archives of cardiovascular imaging

جلد ۲، شماره ۲، صفحات ۰-۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023