retracted article: measurement of central venous pressure using ultrasound in emergency department

نویسندگان

ahmad abbasian department of emergency medicine, pre-hospital emergency research center, imam khomeini hospital , tehran university of medical sciences, tehran, ir iran

hamideh feiz disfani department of emergency medicine, hasheminejad hospital, faculty of medicine, mashhad university of medical sciences, mashhad, ir iran

mohammad afzalimoghaddam department of emergency medicine, imam khomeini hospital, tehran university of medical sciences, tehran, ir iran

mohammad taghi talebian department of emergency medicine, pre-hospital emergency research center, imam khomeini hospital , tehran university of medical sciences, tehran, ir iran

چکیده

conclusions noninvasive assessment of the patient hydration condition using the ultrasound is a simple and practicable measure in emergency. with regard to the considerations, it is possible to estimate cvp via diameter measurement and cross-section of the central veins. results twenty patients with the mean age of 60.3 were studied. the main reason for cardiac catheterization was shock. there are no relationship between anterior posterior diameter of inferior vena cava and cvp of patients (p = 0.257). the longest diameter of ivc in ultrasonographic transverse view had significant association with cvp of patients (p = 0.045) but in patients with bmi > 25 it was not significant. cross section of internal jugular vein had significant association with cvp of patients (p = 0.003). longitudinal diameter of internal jugular vein had no significant association with cvp of patients (p = 0.052), but transverse diameter of internal jugular generally had significant association with cvp of patients (p = 0.003). cross section of internal jugular had significant association with cvp (p = 0.001). background in order to assessment of intravascular fluid measurement of central venous pressure (cvp) is used via central venous catheterization (cvc). this procedure is highly invasive and may cause serious complications such as pneumothorax, infection, hematoma and etc. it is so valuable procedure if we can uses a less invasive or noninvasive procedure to assess patients intravascular fluid in critical positions. objectives in this study, the ultrasound was used to measure the central venous pressure (cvp). patients and methods in this study, patients with central venous catheterization were selected using simple random sampling. the largest diameter of longitudinal, transverse views and the cross-section of inferior vena cava (ivc) and internal jugular vein (ijv) were measured using the ultrasound in the bedside of the patients. central venous pressure was measured using routine methods. correlations between variables were analyzed using spss and linear regression.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Central Venous Pressure Using Ultrasound in Emergency Department

BACKGROUND In order to assessment of intravascular fluid measurement of central venous pressure (CVP) is used via central venous catheterization (CVC). This procedure is highly invasive and may cause serious complications such as pneumothorax, infection, hematoma and etc. It is so valuable procedure if we can uses a less invasive or noninvasive procedure to assess patients intravascular fluid i...

متن کامل

An Evaluation of Complications in Ultrasound-Guided Central Venous Catheter Insertion in the Emergency Department

OBJECTIVES In emergency departments, emergency physicians frequently have to perform central venous access. In cases where peripheral venous access is not possible, central venous access is required for dialysis, fulfillment of urgent fluid need, or central venous pressure measurement. This study was carried out to evaluate the emergence of complications in the process of and in the 15 days fol...

متن کامل

Determination of Central Venous Pressure from Intraocular Pressure

Background: In many clinical situations, knowledge of central venous pressure (CVP) is important.  Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery.  Those with carotid artery or jugular venous diseases as we...

متن کامل

Should ultrasound guidance be used for central venous catheterisation in the emergency department?

In September 2002, the National Institute of Clinical Excellence (NICE) issued guidelines for England and Wales suggesting that ultrasound guidance should be used for all electives, and should be considered for most emergency, central venous catheterisations.1 These guidelines propose a major change of practice for most clinicians practising in UK Emergency Departments. There are also resource ...

متن کامل

Ultrasound assistance for central venous catheter placement in a pediatric emergency department improves placement success rates.

OBJECTIVES The use of ultrasound (US) has been shown to improve success rates and reduce complications of central venous catheter (CVC) placement in adult emergency department (ED) patients. The authors sought to determine if US assistance for CVC placement is associated with an increased success rate in pediatric ED patients. METHODS This was a retrospective cohort study of CVC placement in ...

متن کامل

A new central venous access in Emergency Department: ultrasound-guided infraclavicular axillary vein

Results 52 year old woman addicted to parenteral drugs, stage C3 HIV with 2 weeks duration fever. On arrival had malaise, hypotensive, febrile, tachycardic... it was not possible to catheterize a peripheral vein we performed a central line cannulation: ultrasound-guided infraclavicular axillary vein. Less arterio-venous overlap and a greater distance between artery and vein and from vein to rib...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian red crescent medical journal

جلد ۱۷، شماره ۱۲، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023