simultaneous pre-concentration of cadmium and lead in environmental water samples with dispersive liquid-liquid microextraction and determination by inductively coupled plasma-atomic emission spectrometry
نویسندگان
چکیده
the dispersive liquid–liquid microextraction (dllme) method for determination of pb +2 and cd +2 ions in the environmental water samples was combined with inductively coupled plasma-atomic emission spectrometry (icp-aes). ammonium pyrrolidine dithiocarbamate (apdc), chloroform and ethanol were used as chelating agent, extraction solvent and disperser solvent, respectively. some effective parameters on the microextraction and the complex formation were selected and optimized. these parameters included extraction and disperser solvent type as well as their volume, extraction time, salt effect, ph, sample volume and amount of the chelating agent. under the optimum conditions, the enrichment factor of 75 and 105 for cd +2 and pb +2 ions respectively was obtained from only 5.00ml of water sample. the detection limit (s/n=3) was 12 and 0.8ngml −1 for pb and cd respectively. the relative standard deviation (rsds) for five replicate measurements of 0.50 mgl −1 of lead and cadmium was 6.5 and 4.4 % respectively. mineral, tap, river, sea, dam and spiked water samples were analyzed for cd and pb amount.
منابع مشابه
Preconcentration and determination of palladium water samples by ionic liquid - dispersive liquid liquid microextraction combined with flame atomic absorption spectrometry
A simple, rapid and efficient dispersive liquid–liquid microextraction by use of ionic liquid (IL-DLLME)method, followed by flame atomic absorption spectrometry (FAAS) was developed for the preconcentrationand determination of palladium in water samples. In this method, an appropriate mixture of acetone and octylmethyl imidazolium hexafluorophosphate was injected rapidly into the aqueous sample...
متن کاملpreconcentration and determination of palladium water samples by ionic liquid - dispersive liquid liquid microextraction combined with flame atomic absorption spectrometry
a simple, rapid and efficient dispersive liquid–liquid microextraction by use of ionic liquid (il-dllme)method, followed by flame atomic absorption spectrometry (faas) was developed for the preconcentrationand determination of palladium in water samples. in this method, an appropriate mixture of acetone and octylmethyl imidazolium hexafluorophosphate was injected rapidly into the aqueous sample...
متن کاملDispersive Liquid-Liquid Microextraction of Bismuth in Various Samples and Determination by Flame Atomic Absorption Spectrometry
A dispersive liquid-liquid microextraction method for the determination of bismuth in various samples by flame atomic absorption spectrometry is described. In this method, crystal violet was used as counter positive ion for BiCl4 (-) complex ion, chloroform as extraction solvent, and ethanol as disperser solvent. The analytical parameters that may affect the extraction efficiency like acidity o...
متن کاملDetermination of Cobalt in Food, Environmental and Water Samples with Preconcentration by Dispersive Liquid-Liquid Microextraction
A new method for the determination of cobalt was developed by dispersive liquid-liquid microextraction preconcentration and flame atomic absorption spectrometry. In the proposed approach, 1,5-bis(di-2-pyridyl) methylene thiocarbohydrazide (DPTH) was used as a chelating agent, and chloroform and ethanol were selected as extraction and dispersive solvents. Some factors influencing the extraction ...
متن کاملSelective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry
In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...
متن کاملTungsten coil atomic emission spectrometry combined with dispersive liquid-liquid microextraction: A synergistic association for chromium determination in water samples.
A novel and environment friendly analytical method is reported for total chromium determination and chromium speciation in water samples, whereby tungsten coil atomic emission spectrometry (WCAES) is combined with in situ ionic liquid formation dispersive liquid-liquid microextraction (in situ IL-DLLME). A two stage multivariate optimization approach has been developed employing a Plackett-Burm...