ultra-trace determination of copper and silver in environmental samples by using ionic liquid-based single drop microextraction-electrothermal atomic absorption spectrometry

نویسندگان

j. abolhasani department of chemistry, faculty of science, tabriz branch, islamic azad university, tabriz, iran

m. amjadi department of analytical chemistry, faculty of chemistry, university of tabriz, tabriz, iran

e. ghorbani kalhor department of chemistry, faculty of science, tabriz branch, islamic azad university, tabriz, iran

چکیده

a sensitive, selective and effective ionic liquid-based single drop microextraction technique was developed by using ionic liquid, 1-hexyl-3-methylimidazolium hexafluorophosphate, c6mimpf6, coupled with electrothermal atomic absorption spectrometry (etaas) for the determination of copper and silver in environmental samples. dithizone was used as chelating agent. several factors that influence the microextraction efficiency and etaas signal, such as ph, dithizone concentration, extraction time, amounts of ionic liquid, stirring rate, pyrolysis and atomization temperature were investigated and the microextraction conditions were established. in the optimum experimental conditions, the detection limits (3 s) of the method were 4 and 8 ng l-1 and corresponding relative standard deviations (0.1 μg l-1, n = 6) were 4.2% and 4.8% for ag and cu, respectively. the developed method was validated by analysis of a certified reference material and applied to the determination of silver and copper.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preconcentration and determination of palladium water samples by ionic liquid - dispersive liquid liquid microextraction combined with flame atomic absorption spectrometry

A simple, rapid and efficient dispersive liquid–liquid microextraction by use of ionic liquid (IL-DLLME)method, followed by flame atomic absorption spectrometry (FAAS) was developed for the preconcentrationand determination of palladium in water samples. In this method, an appropriate mixture of acetone and octylmethyl imidazolium hexafluorophosphate was injected rapidly into the aqueous sample...

متن کامل

Ion Pair Dispersive Liquid-Liquid Microextraction for the Determination of Trace Amounts of Copper(II) in Soil, Multivitamin Tablet, Tea and Water Samples Using Flame Atomic Absorption Spectrometry

Ion pair dispersive liquid- liquid microextraction (IP-DLLME) method combined with flame atomic absorption spectrometry was proposed for the determination of trace amounts of copper(II). By using pyrocatechol violet as chelating agent and cetyltrimethyl ammonium bromide as an ion pairing agent, the trace amount of copper(II) was extracted in chloroform. The factors influencing the formation cop...

متن کامل

Dispersive liquid–liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry for determination trace amount of cobalt in water samples

An efficient, rapid, simple, and highly selective dispersive liquid–liquid microextraction basedon solidification of floating organic drop (DLLME-SFOD), combined with flame atomicabsorption spectrometry was developed for preconcentration and determination of trace amountsof cobalt in water samples. In this method, an appropriate mixture of acetone and1-undecanol was injected rapidly into the aq...

متن کامل

Ionic Liquid-Based Dispersive Liquid-Liquid Microextraction Combined with Flame Atomic Absorption Spectrometry for Determination of Silver in Water Samples

The widespread use of silver compounds and silvercontaining procedures in industry, medicine, jewellery, cloud seeding and in disinfection of drinking water has resulted in an increasing silver content in environmental samples. Silver impregnated filters are used in water disinfection, while silver concentrations up to 200 μg L are permitted for antimicrobial activities for human health. Silver...

متن کامل

Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop

The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...

متن کامل

Dispersive Liquid-Liquid Microextraction Based on Solidification of Floating Organic Drop Combined with Flame Atomic Absorption Spectrometry for Preconcentration and Determination of Thallium(III) in Water Samples

Dispersive Liquid-Liquid MicroExtraction technique based on Solidification of a Floating Organic drop (DLLME-SFO) combined with flame atomic absorption spectrometry was developed for determination of thallium in water sample. An appropriate mixture of acetone and 1-undecanol was rapidly injected into an aqueous sample containing TlCl4- which forms an ion pair with bril...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of chemical health risks

جلد ۳، شماره ۳، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023