a comparative study of three speckle reducing methods for intima-media thickness ultrasound images

نویسندگان

mehravar rafati department of medical physic and radiology, faculty of paramedical sciences, kashan university of medical science, kashan, ir iran

masoud arabfard department of basic sciences, kish international campus, university of tehran, kish island, ir iran

mehrdad rafati rahimzadeh department of nursing, babol university of medical sciences, babol, ir iran

hasan voshtani department of cardiology, heshmat cardiovascular research center, guilan university of medical sciences, rasht, ir iran; department of cardiology, heshmat cardiovascular research center, guilan university of medical sciences, rasht, ir iran. tel: +98-1333663070, fax: +98-1316668718

چکیده

conclusions by measuring image quality metrics, this study showed that dtd and ctd filters with the canny edge detection respectively, are better than srad filter with the canny detection for speckle suppression and details preservation in both arteries in the ultrasound images. background ultrasonic evaluation of intima-media thickness (imt) is an early marker of assessing the development of atherosclerosis and determining cardiovascular risk. to attain the best possible diagnosis, it is essential that medical images be clear, sharp and without noise and artifacts. objectives comparison of speckle reducing anisotropic diffusion (srad), discrete (dtd) and continuum topological derivative (ctd) on b-mode ultrasound images of common carotid and brachial arteries throughout the cardiac cycle. patients and methods in a cross-sectional design, an examination was performed on forty-two human subjects with a mean age of 44 ± 6 years from april 2013 to june 2013. this study was approved by the ethics committees of kashan university of medical sciences and beheshti hospital. an ultrasonic examination of common carotid and brachial arteries of forty-two human subjects was performed. the program was designed in matlab software to extract consecutive b-mode images and apply region of interest (roi) on the imt of the common carotid and brachial arteries. then, three different noise reduction filters with the canny edge detection were used in roi separately. finally, the program measured the image quality metrics. results according to values of eleven different image quality metrics (mentioned in the main text), there was a significant difference between ctd, dtd and srad filters with the canny edge detection status in the common carotid and brachial arteries throughout the cardiac cycle (all p values < 0.001). for example, peak signal to noise ratios (psnr) using ctd, dtd and srad filters were 95.43 ± 0.64, 88.86 ± 0.82 and 73.02 ± 0.20 in common carotid and 96.39 ± 1.25, 92.58 ± 0.11 and 88.27 ± 0.63 in brachial arteries, respectively (both p values < 0.001).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study of Three Speckle Reducing Methods for Intima-Media Thickness Ultrasound Images

BACKGROUND Ultrasonic evaluation of intima-media thickness (IMT) is an early marker of assessing the development of atherosclerosis and determining cardiovascular risk. To attain the best possible diagnosis, it is essential that medical images be clear, sharp and without noise and artifacts. OBJECTIVES Comparison of speckle reducing anisotropic diffusion (SRAD), discrete (DTD) and continuum t...

متن کامل

Automated identification of Intima Media Thickness in Ultrasound Artery Images

In this paper presents identification of intima media thickness (IMT) in common carotid Artery ultrasound video sequence. It is fully using automatic segmentation, these are based on unsupervised manner. The aim of this study introduces a novel unsupervised Computer Aided Detection (CAD) Algorithm that is able to identify and measure the IMT in 2D ultrasound carotid images. The developed techni...

متن کامل

Speckle Reducing Filtering for Ultrasound images

Speckle noise is undesired result which appear during the image formation process in that is most typically known to occur in the coherent imaging systems for example ultrasound imaging, sonar, lasers, synthetic aperture radar and many more. So the presence of speckle in ultrasound imaging system results in decrease in quality of image and it become quite difficult for human to diagnose and int...

متن کامل

Speckle Noise Reduction from Medical Ultrasound Images-A comparative study

In medical image processing image denoising has become a very essential exercise all through the diagnose. Medical images are often deteriorated by noise due to a serious sources of interferences and other phenomenon that affect the measurement process in an imaging and acquisition system. Speckle noise is a random mottling of the image with bright and dark spots, which obscures fine details an...

متن کامل

a comparative study of the theme of "marriage" in three victorian novelists: charles dickens, george eliot and thomas hardy

این تحقیق کوشیده است با انتخاب پنج رمان از میان آثار برگزیده، «چارلز دیکنز»، «جورج الیوت» و «توماس هاردی » و با رویکردی تطبیقی به بررسی درونمایه ی «ازدواج» در آثار این سه رمان نویس بزرگ دوره ی ویکتوریا بپردازد. فرضیه ی اولیه ی تحقیق این بوده است که چارلز دیکنز (1870- 1812) با زبانی شوخ و گزنده، جورج الیوت(1880- 1819) با نگاهی آموزشی–اندرزگونه و توماس هاردی(1928- 1840) با رویکردی تلخ وانتقادی به...

Speckle reducing anisotropic diffusion for 3D ultrasound images.

This paper presents an approach for reducing speckle in three dimensional (3D) ultrasound images. A 2D speckle reduction technique, speckle reducing anisotropic diffusion (SRAD), is explored and extended to 3D. 3D SRAD is advantageous in that, like 2D SRAD, it keeps the advantages of the conventional anisotropic diffusion and the traditional speckle reducing filter, the Lee filter, by exploitin...