optimal stent expansion by stent balloon multiple inflation at nominal pressure in resistant lesions: a new technique

نویسندگان

amir hossein khosh nasab resident of cardiology, faculty of medicine, mashhad university of medical sciences, mashhad, iran

mahmoud mohammadzadeh shabestri cardiologist,faculty of medicine, mashhad university of medical sciences, mashhad, iran

ali eshraghi cardiologist,faculty of medicine, mashhad university of medical sciences, mashhad, iran

majid jalalyazdi cardiologist, faculty of medicine, mashhad university of medical sciences, mashhad, iran

چکیده

introduction: this study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. materials and methods: this interventional study was conducted on 39 patients with coronary artery lesions, in whom zotarolimus-eluting stents (n=20), paclitaxel-eluting stents (n=11) and other stents (n=8) were deployed four times at nominal inflation pressure and increased inflation times (5, 15, 30 and 45 seconds). after the deployments, enhanced stent visualization imaging technique (ic stent) was used to assess stent placement and artery expansion. results: in this study, early success rate was estimated at 79.5% using the enhanced stent visualization imaging technique. in addition, major adverse cardiac event (mace) was determined at 2.6%. also, conventional methods resulted in lower success rate and higher mace in resistant lesions. conclusion: according to the results of this study, four-time stent balloon inflation at nominal pressure could allow adequate stent expansion in resistant lesions leading to lower mace.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique

Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...

متن کامل

Coronary stent implantation technique: prolonged inflation time maximizes stent expansion.

OBJECTIVES To determine whether longer periods of stent balloon inflation result in greater minimal luminal diameter (MLD) as measured by quantitative coronary analysis (QCA), and to determine whether measured size correlated with that predicted by pressure-diameter nomograms. METHODS Seventy-four stents were implanted in 52 patients. Stent acquisitions at a steady inflation pressure were tak...

متن کامل

Aggressive plaque modification with rotational atherectomy and cutting balloon for optimal stent expansion in calcified lesions

OBJECTIVE To evaluate the factors affecting optimal stent expansion in calcified lesions treated by aggressive plaque modification with rotational atherectomy (RA) and a cutting balloon (CB). METHODS From January 2014 to May 2015, 92 patients with moderate to severe coronary calcified lesions underwent rotational atherectomy and intravascular ultrasound imaging at Chinese PLA General Hospital...

متن کامل

Staged inflation: An approach with achievement of optimal luminal gain and reduced rate of spontaneous coronary artery dissection.

Introduction Nowadays, interventional cardiology brought a great success to the treatment of many cardiovascular disorders. Despite these great beneficial effects, it has side effects related to the applied techniques. Among them, inflation pressure and pattern of inflation play fundamental role in this regard. By low and very high inflation pressures, the rate of stent thrombosis and in-stent ...

متن کامل

"Stent-Within-a-Stent Technique": Nothing New Under the Sun.

Dear Editor: We read with interest the report by Metha and colleagues regarding the use of a stent within a stent for the treatment of dissecting vertebral artery aneurysms (1). It would seem to have been appropriate for these authors to cite our earlier report regarding the use of this technique (2, 3). Writing and publishing scientific papers is facilitated by the availability of modern elect...

متن کامل

Plastic Biliary Stent Migration During Multiple Stents Placement and Successful Endoscopic Removal Using Intra-Stent Balloon Inflation Technique: A Case Report and Literature Review

BACKGROUND Late migration of a plastic biliary stent after endoscopic placement is a well known complication, but there is little information regarding migration of a plastic stent during multiple stents placement. CASE REPORT A white man was hospitalized for severe jaundice due to neoplastic hilar stenosis. Surgical eligibility appeared unclear on admission and endoscopy was carried out, but...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of cardio-thoracic medicine

جلد ۳، شماره ۳، صفحات ۳۴۰-۳۴۳

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023