influences of reconstruction and attenuation correction in brain spect images obtained by the hybrid spect/ct device: evaluation with a 3‐dimensional brain phantom
نویسندگان
چکیده
objective: the aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123i brain spect obtained by the hybrid spect/ct device. methods: we used the 3-dimensional (3d) brain phantom, which imitates the precise structure of gray mater, white matter and bone regions. it was filled with 123i solution (20.1 kbq/ml) in the gray matter region and with k2hpo4 in the bone region. the spect/ct data were acquired by the hybrid spect/ct device. spect images were reconstructed by using filtered back projection with uniform attenuation correction (fbp-uac), 3d ordered-subsets expectation-maximization with uniform ac (3d-osem-uac) and 3d osem with ct-based non-uniform ac (3d-osem-ctac). we evaluated the differences in the radioactivity distributions among these reconstruction methods using a 3d digital phantom, which was developed from ct images of the 3d brain phantom, as a reference. the normalized mean square error (nmse) and regional radioactivity were calculated to evaluate the similarity of spect images to the 3d digital phantom. results: the nmse values were 0.0811 in fbp-uac, 0.0914 in 3d-osem-uac and 0.0766 in 3d-osem-ctac. the regional radioactivity of fbp-uac was 11.5% lower in the middle cerebral artery territory, and that of 3d-osem-uac was 5.8% higher in the anterior cerebral artery territory, compared with the digital phantom. on the other hand, that of 3d-osem-ctac was 1.8% lower in all brain areas. conclusion: by using the hybrid spect/ct device, the brain spect reconstructed by 3d-osem with ct attenuation correction can provide an accurate assessment of the distribution of brain radioactivity.
منابع مشابه
Influences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3‐dimensional brain phantom
Objective: The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123I brain SPECT obtained by the hybrid SPECT/CT device. Methods: We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray mater, white matter and bone regions. It was filled with 123I solution (20...
متن کاملInfluences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3-dimensional brain phantom
OBJECTIVES The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in (123)I brain SPECT obtained by the hybrid SPECT/CT device. METHODS We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray matter, white matter and bone regions. It was filled with (123)I soluti...
متن کاملEvaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom
Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...
متن کاملEvaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT Images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators
Objective(s): The purpose of this study was to examine the optimal reconstruction parameters for brain dopamine transporter SPECT images obtained with a fan beam collimator and compare the results with those obtained by using parallel-hole collimators.Methods: Data acquisition was performed using two SPECT/CT devices, namely a Symbia T6 and an Infinia Hawkeye 4 (device A and B) equipped with fa...
متن کاملEvaluation of attenuation correction process in cardiac SPECT images
Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...
متن کاملevaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter spect using anthropomorphic striatal phantom
objective(s): the aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (dat) single-photon emission computed tomography (spect). the results were compared between filtered back projection (fbp) and different attenuation correction (ac) methods.methods: an anthropomorphic striatal phant...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
asia oceania journal of nuclear medicine and biologyجلد ۲، شماره ۱، صفحات ۲۴-۲۹